1. Вовед

The SINOTIMER DDS529MR is a single-phase AC electricity energy meter designed for measuring active energy (kWh), voltage, current, power, frequency, and power factor. It features RS485 Modbus RTU communication for remote data acquisition and a pulse output for energy monitoring. The meter is designed for 35mm DIN rail installation, making it suitable for various electrical distribution systems.

A variant, the DDS529R, is also available, which displays only kWh.

Предна страна view of the DDS529MR energy meter showing its display and buttons.
Слика 1: Предна страна view of the DDS529MR Energy Meter

2. Информации за безбедност

  • Инсталацијата и одржувањето треба да ги врши само квалификуван персонал.
  • Пред инсталација или поврзување, осигурајте се дека целата струја е исклучена за да се спречи електричен удар.
  • Следете ги сите локални и национални електрични кодови и прописи.
  • Do not operate the meter if it appears damaged.
  • The meter is designed for indoor use in a dry environment.

3. Содржина на пакетот

По отварањето на пакувањето, проверете дали сите предмети се присутни и неоштетени:

  • 1 x DDS529MR (or DDS529R) Energy Meter
  • 1 x English Operation Manual

4. Спецификации

ПараметарВредност
Број на моделDDS529MR
Име на брендотСИНОТИМЕР
Оценета струја5A
Максимална оперативна струја80 А
Оценето волtage230V AC
Излез Voltage230V AC
НапојувањеAC
ФазаЕднофазен
Тип на дисплејDigital Only (LCD)
Display (DDS529MR)KWh, Voltage, Current, Power, Frequency, Power Factor
Мерење на енергетскиот опсег0 до 999999.9 kWh
Класа на точност1
Фреквенција на пулсот1000 imp / kWh
Протокол за комуникацијаRS485 Modbus RTU
Работна температура-10 до 50 °C
Димензии (Д*Ш*В)100 мм * 65 мм * 35 мм
Инсталација35мм DIN шина
СертификацијаCE
Вклучена батеријабр
Diagram showing the dimensions of the energy meter: 100mm height, 65mm width, 35mm depth, and 45mm depth for the DIN rail mount.
Figure 2: Meter Dimensions

5. Поставување и инсталација

5.1 Монтирање на DIN шина

The DDS529MR energy meter is designed for standard 35mm DIN rail installation. Simply clip the meter onto the DIN rail in your electrical panel.

5.2 Инструкции за поврзување

WARNING: Ensure all power is OFF before proceeding with wiring. Incorrect wiring can cause damage to the meter, property, or personal injury.

The meter uses a 2-wire single-phase connection. Refer to the wiring diagram below for proper connections.

Wiring diagram for the DDS529MR energy meter. Terminals 1 and 4 are labeled as INPUT (L and N respectively). Terminals 2 and 3 are labeled as OUTPUT (L and N respectively). RS485 terminals A and B, and pulse output terminals SO+ and SO- are also shown.
Figure 3: Main Power and Pulse Output Wiring Diagram
  • Влез на енергија: Connect the Live (L) wire to terminal 1 and the Neutral (N) wire to terminal 4.
  • Излезна моќност: Connect the Live (L) wire to terminal 2 and the Neutral (N) wire to terminal 3.
  • RS485 Комуникација: Connect RS485 A to terminal A and RS485 B to terminal B. (Refer to the side view image for terminal locations).
  • Излез на пулсот: Connect the pulse output (SO+, SO-) to terminals 21 and 20 respectively for external pulse counting.
Аголна view of the DDS529MR meter showing all terminal labels for power, RS485 (A, B, 23, 24), and pulse output (SO+, SO-).
Слика 4: Страна view showing all terminals

After wiring, ensure all terminal screws are tightened securely. Close the terminal cover before restoring power.

6. Упатства за работа

6.1 Display Functions (DDS529MR)

The DDS529MR model features a multifunctional LCD display that cycles through various electrical parameters. Use the 'TURN' button to manually cycle through the display modes. The 'SET' button is typically used for configuration, though specific advanced settings may require the RS485 interface.

Diagram illustrating the various display parameters of the DDS529MR meter: power consumption (kWh), voltage (V), current (A), power (W), power factor (PF), and frequency (Hz).
Figure 5: DDS529MR Display Parameters

The display typically shows:

  • kWh: Total accumulated active energy consumption.
  • V: Моментален томtage.
  • A: Instantaneous current.
  • W: Instantaneous active power.
  • ПФ: Фактор на моќност.
  • Hz: Фреквенција.

The DDS529R model will only display kWh.

6.2 Pulse LED Indicator

A pulse LED on the front panel indicates the working status of the meter. It flashes at a rate of 1000 impulses per kWh, providing a visual confirmation of energy consumption.

6.3 Display Cycling Demonstration

Watch this video to see the meter's display cycling through different parameters:

Video 1: Demonstration of the energy meter's display cycling through various readings like address, baud rate, and kWh.

7. Одржување

  • Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Редовно проверувајте ги сите жичени врски за да бидете сигурни дека се безбедни.
  • Ensure the operating environment stays within the specified temperature and humidity ranges.

8 Смена на проблеми

8.1 No Display / Meter Not Powering On

  • Check the main power supply to ensure it is active.
  • Verify that the Live (L) and Neutral (N) wires are correctly connected to terminals 1 and 4 respectively, and that connections are secure.
  • Обезбедете оценет voltage (230V AC) is supplied to the meter.

8.2 Неточни отчитувања

  • Confirm that the wiring for input and output is correct as per the diagram (Figure 3).
  • Ensure the load connected is within the meter's maximum current rating (80A).

8.3 RS485 Communication Issues

  • Check the RS485 A and B connections for correct polarity and secure contact.
  • Verify the communication settings (baud rate, parity, data bits, stop bits) on your Modbus master device match the meter's settings.
  • Ensure the RS485 Modbus RTU document is consulted for detailed communication protocols.

9. Кориснички совети

  • For accurate energy monitoring, ensure the meter is installed in a stable environment, free from excessive vibrations or extreme temperatures.
  • When using the RS485 communication, it is recommended to use shielded twisted-pair cables to minimize interference.
  • Periodically record kWh readings to track energy consumption trends over time.

10. Гаранција и поддршка

For any technical support, warranty claims, or inquiries regarding the RS485 Modbus document, please contact the seller or manufacturer directly. Provide your product model (DDS529MR) and any relevant purchase information for faster assistance.