1. Вовед
The ANCEL S110 is a professional automotive smoke leak detector designed to quickly and accurately diagnose leaks in various vehicle systems. This compact and easy-to-use device is essential for mechanics and DIY enthusiasts to identify issues in EVAP systems, intake systems, exhaust systems, and other pipeline systems, preventing costly repairs and ensuring optimal vehicle performance.
It features dual operating modes (Air Mode and Smoke Mode), a built-in air pump, and robust temperature protection, making it a reliable tool for comprehensive leak detection across a wide range of vehicles.
2. Информации за безбедност
- Секогаш ракувајте со уредот во добро проветрена просторија.
- Do not inhale the smoke produced by the device.
- Ensure the vehicle engine is off and cool before connecting the device.
- Use only recommended test fluids (baby oil or olive oil). Do not use flammable liquids.
- Keep the device away from open flames or sparks.
- Носете соодветна лична заштитна опрема, вклучувајќи заштитни очила и ракавици.
- Do not exceed the maximum oil level indicated on the device.
- Disconnect power when not in use or during maintenance.
- Avoid using on windy environments when performing cabin air leak detection.
3. Содржина на пакетот
The ANCEL S110 package includes all necessary accessories for immediate use:
- ANCEL S110 Smoke Leak Detector Unit
- Power Cord (with battery clamps)
- Црево за испорака
- Кука
- Инка
- EVAP Adapters
- Приклучок за воздушна пумпа
4. Спецификации
| Карактеристика | Спецификација |
|---|---|
| Име на моделот | ANCEL S110 |
| Voltage | DC 12V |
| Излезен волумен | < 8LPM |
| Smoke Current | 5 AMP |
| Излезен притисок | 0.5psi |
| Тест течност | Baby oil or olive oil (Not included) |
| Заштита од прегревање | Automatic power off when temperature exceeds 75℃ |
| Anti-frost Protection | Operates normally at -20℃ |
| Димензии | 4.88 x 4.21 x 6.53 инчи |
| Тежина | 2 фунти |
| Vehicle Type Compatibility | Motorcycle, Passenger Vehicle (Cars, ATVs, Snowmobiles, Light Trucks, Speedboats) |
5. Упатства за поставување
Follow these steps to prepare your ANCEL S110 for leak detection:
- Прикачете ја куката: Securely attach the provided hook to the device for convenient hanging on the engine hood.
- Connect Workshop Air Adapter: Attach the workshop air adapter to the designated port on the unit.
- Приклучете го кабелот за напојување: Connect the power cord to the power outlet on the device.
- Screw in Smoke Hose: Screw the smoke delivery hose to the smoke outlet port on the unit.
- Fill Smoke Oil: Using the funnel, fill smoke oil (baby oil or olive oil) into the refill opening on the top of the unit. Note: The oil level must not be higher than the level indicator.
- Connect Factory Air Supply: Connect your external air supply to the workshop air adapter.
- Поврзете го напојувањето на возилото: Поврзете го кабелот за напојување clamps to the vehicle's 12V battery terminals (red to positive, black to negative).
6. Упатства за работа
The ANCEL S110 offers two primary operating modes: Air Mode and Smoke Mode.
6.1 Општа операција
- After completing the setup, turn the flow control knob counterclockwise to open the air flow.
- Turn on the power switch located on the back of the unit. The unit will begin to generate air or smoke depending on the selected mode.
- Introduce the smoke/air into the system you wish to test using the delivery hose and appropriate adapters.
6.2 Air Mode
Air Mode allows for preliminary leak testing without consuming smoke oil. This mode is ideal for quickly confirming the presence of a leak before proceeding to smoke detection.
- Place the delivery hose into the area to be tested.
- Observe the small red ball on the flow meter and the pressure gauge.
- If the pressure gauge value is less than 0.5 bar, a leak is present. If it reaches 0.8 bar or above, the pipeline tightness is good.
6.3 Smoke Mode
Once a leak is suspected using Air Mode, switch to Smoke Mode to visually locate the exact point of failure. Smoke is typically produced within 10 seconds.
- Ensure sufficient smoke oil is in the reservoir.
- Introduce smoke into the vehicle system.
- Visually inspect for smoke escaping from any part of the system, indicating a leak.
- The adjustable rotary button allows you to freely adjust the amount of smoke output for optimal visibility.
6.4 Interpreting Pressure Gauge & Flow Meter
The integrated pressure gauge and adjustable flow meter provide crucial information about the leak status:
- NO Leak: When the pressure gauge value remains unchanged and the flow meter reads zero (ball at bottom of scale), there is no leakage in the system.
- Мало истекување: If the pressure gauge value drops and the ball in the flow meter slowly falls to the bottom of the scale, it indicates a small leak.
- Масивно истекување: When the pressure gauge value reaches zero and the flow meter ball never falls to the bottom of the scale, it indicates a large leak.
6.5 Апликации
The ANCEL S110 is suitable for detecting leaks in various vehicle systems, including but not limited to:
- Тест на EVAP системот: Detects leaks in the fuel evaporation system to prevent fuel vapor escape and unstable engine idling.
- Exhaust System Test: Identifies leaks causing uncleaned harmful gases or increased vehicle noise.
- Fuel Tank System Test: Locates gaps in the fuel tank and pipes due to improper installation or sealing.
- Various Pipe Connections: Smoke test for brake hoses, power steering hoses, cooling system hoses, air conditioning system hoses, turbocharger hoses, fuel hoses, intake and exhaust system hoses.
- Car Sealing Test: Checks for poor sealing in the car cabin that can lead to issues like dust, noise, or water leaks.
- Crankcase System Test: Detects excessive pressure or corrosion leading to crankcase seal damage and oil leaks.
- Intake System Test: Identifies leaks causing inadequate engine intake and low performance.
- Turbo Test: Checks for coolant leakage that could cause high water temperature indications.
7. Одржување
- Refilling Smoke Oil: Regularly check the oil level indicator. Refill with baby oil or olive oil when the level is low, ensuring not to overfill past the maximum indicator.
- Чистење: Избришете ја надворешноста на уредот со мека, сува крпа. Не користете абразивни средства за чистење или растворувачи.
- Складирање: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Ensure all hoses and accessories are properly stored to prevent damage.
- Инспекција на цревото: Periodically inspect the delivery hose and adapters for any signs of wear, cracks, or damage. Replace if necessary to ensure effective sealing.
8 Смена на проблеми
8.1 No Smoke Output
- Check if the power is connected correctly and the device is turned on.
- Ensure there is sufficient smoke oil in the reservoir.
- Verify that the air supply is connected and active.
- Check if the flow control knob is open.
8.2 Inaccurate Leak Detection
- Ensure all connections are tight and there are no leaks in the testing setup itself.
- Verify that the system being tested is properly sealed off from the atmosphere, except for the point of smoke/air introduction.
- Re-calibrate your interpretation of the flow meter and pressure gauge based on the guidelines in Section 6.4.
8.3 Прегревање на уредот
- The device has an automatic overheat protection that shuts it off if the temperature exceeds 75℃. Allow the device to cool down before resuming operation.
- Обезбедете соодветна вентилација околу уредот за време на работата.
9. Кориснички совети
- For very small leaks, allow the smoke to build up in the system for a few minutes before inspecting.
- When testing the EVAP system, ensure the fuel cap is securely tightened or sealed to prevent false readings.
- Use a bright flashlight to help spot faint smoke trails, especially in dimly lit areas of the engine bay.
- Always start with Air Mode to quickly assess if a leak exists, saving smoke oil for precise location.
- Consider using a small fan to gently disperse smoke in the general area to make the leak source more visible against a clear background.
10. Гаранција и поддршка
The ANCEL S110 Car Smoke Leak Detector comes with a manufacturer's warranty. For specific warranty terms, duration, and conditions, please refer to the warranty card included with your product or contact the manufacturer directly.
For technical support, troubleshooting assistance, or any questions regarding the operation and maintenance of your device, please contact ANCEL customer service through their official webстраницата или информациите за контакт наведени во пакувањето на вашиот производ.