1. Вовед
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SANDISOLAR 3KW 24V 110V/120V Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.
1.1 Производ надview
The SANDISOLAR SD-HYM-2430HW-US is an off-grid pure sine wave solar inverter designed for various applications, including power generation systems, household use, and PV roof installations. It features a built-in 100A MPPT solar charger and WiFi for remote monitoring.

1.2 Клучни карактеристики
- Излез со чист синусен бран за чувствителна електроника.
- Built-in MPPT 100A solar charger for efficient solar energy harvesting.
- Max PV влезен волуменtage од 500Vdc.
- Integrated WiFi for remote monitoring and control via the SmartESS App.
- Capable of working without a battery.
- Dual output for smart load management.
- Detachable dust cover for protection in harsh environments.
- Compatible with LiFePO4 batteries via RS485 communication.
- Lithium battery activation function via PV or Utility.
- Supports multiple output priorities: UTL (Utility), SOL (Solar), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery).
- EQ (Equalization) function to optimize battery performance and extend lifecycle.

1.3 Апликативни сценарија

2. Безбедносни предупредувања
ПРЕДУПРЕДУВАЊЕ: Опасност од удар
Инсталирањето мора да се изврши внимателно поради големата јачина на батеријатаtage во серија.
ВНИМАНИЕ!!
- Do not place anything between the flat part of the inverter terminal. Otherwise, overheating may occur.
- Не нанесувајте антиоксидантна супстанција на приклучоците пред да се поврзат цврсто.
- Пред да го направите последното поврзување со еднонасочна струја или да го затворите прекинувачот/раскинувачот за еднонасочна струја, проверете дали позитивното (+) мора да биде поврзано со позитивно (+), а негативното (-) мора да биде поврзано со негативно (-).
- ПОГОДЕН ЗА МОНТАЖА САМО НА БЕТОН ИЛИ ДРУГА НЕЗАПАЛИВИ ПОВРШИНИ.
3. Отпакување и проверка
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:
- Инвертерската единица x 1
- User manual x 1 (A detailed PDF user manual is also available for download: Упатство за употреба (PDF))
- WiFi антена x 1
4. Инсталација
4.1 Подготовка
Before connecting all wirings, please remove the bottom cover by unscrewing two screws.
4.2 Монтирање на единицата
Consider the following points when selecting the installation location:
- Не монтирајте го инверторот на запаливи градежни материјали.
- Монтирајте на цврста површина.
- Инсталирајте го овој инвертер во висина на очите за да можете постојано да го читате LCD екранот.
- Температурата на околината треба да биде помеѓу 0°C и 55°C за да се обезбеди оптимална работа.
- The recommended installation position is vertically on the wall.
- Ensure sufficient clearance around the unit for heat dissipation and wire routing, as shown in the diagram below.

Install the unit by screwing three screws. It's recommended to use M4 or M5 screws.
4.3 Поврзување на батеријата
ВНИМАНИЕ:
For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the typical amperage in the table below for required fuse or breaker size.
ПРЕДУПРЕДУВАЊЕ!
All wiring must be performed by qualified personnel. It is critical for system safety and efficient operation to use appropriate cables for battery connection. To reduce risk of injury, use the proper recommended cable and terminals.
| Модел | Максимум Ampбес | Капацитет на батеријата | Големина на жица | Кабел mm² | Terminal Size L(mm) | Terminal Size W(mm) | Terminal Size D(mm) | Вредност на вртежниот момент |
|---|---|---|---|---|---|---|---|---|
| 3 KVA | 137 А | 200 АХ | 2AWG | 35 | 37 | 15.3 | 6.4 | 4~6 Nm |
Следете ги овие чекори за да ја поврзете батеријата:
- Create battery positive and negative cables according to the recommended specifications.
- Поврзете ги сите батерии по потреба.
- Insert battery cables flatly into the inverter's battery connector and ensure bolts are tightened with a torque of 4~6 Nm. Verify correct polarity at both the battery and the inverter/charger.
4.4 Влез/излезен приклучок за наизменична струја
ВНИМАНИЕ!!
Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. The recommended AC breaker specification is 50A. There are two terminal blocks marked “IN” and “OUT”; do NOT mis-connect input and output connectors.
ПРЕДУПРЕДУВАЊЕ!
All wiring must be performed by qualified personnel. It is crucial for system safety and efficient operation to use appropriate cables for AC input connection. To reduce risk of injury, use the proper recommended cable size.
| Модел | Мерач | Вредност на вртежниот момент |
|---|---|---|
| 3 KVA | 10AWG | 1.4~1.6 Nm |
Follow these steps to connect AC input/output:
- Before making AC input/output connections, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to the polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (➔Ground (yellow-green)) first.
- Insert AC output wires according to the polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (➔Ground (yellow-green)) first.
- Проверете дали сите жици се безбедно поврзани.
ВНИМАНИЕ: Важно
Ensure AC wires are connected with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuiting when inverters operate in parallel. Appliances like air conditioners require 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation.
4.5 PV поврзување
ВНИМАНИЕ:
Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
ПРЕДУПРЕДУВАЊЕ!
All wiring must be performed by qualified personnel. It is very important for system safety and efficient operation to use appropriate cables for PV module connection. To reduce risk of injury, use the proper recommended cable size.
| Модел | Типично Ampбес | Големина на кабел | Вртежен момент |
|---|---|---|---|
| 3 KVA | 27 А | 10 AWG | 1.4~1.6 Nm |
Избор на PV модул:
When selecting PV modules, consider these parameters:
- Отвореното коло Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage на инверторот.
- Отвореното коло Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| МОДЕЛ ИНВЕРТЕР | 3 KVA |
|---|---|
| Макс. PV Array Open Circuit Voltage | 500 VDC |
| PV Array MPPT Voltagе опсег | 60VDC~500VDC |
| Макс. PV ВЛЕЗНА СТРУЈА | 27 А |
Follow these steps for PV module wire connection:
- Remove 6mm of insulation sleeve for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) of PV input connector, and negative pole (-) to negative pole (-) of PV input connector.
- Проверете дали сите жици се безбедно поврзани.
4.6 Завршно собрание
Откако ќе ги поврзете сите жици, вратете го долниот капак со навртување на двата завртки назад на место.

5. Операција
5.1 ВКЛУЧУВАЊЕ/ИСКЛУЧУВАЊЕ
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.

5.2 Панел за работа и приказ
The front panel of the inverter includes an LCD display, three indicators, and four function keys, providing operating status and input/output power information.


| LED индикатор | Боја | Пораки |
|---|---|---|
| AC/INV | Зелена | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG | Зелена | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| ВИНА | Црвено | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
| Функциски клуч | Опис |
|---|---|
| ESC | За да излезете од режимот на поставување. |
| UP | To go to previous selection. |
| ДОЛУ | To go to next selection. |
| ENTER | To confirm the selection in setting mode or enter setting mode. |
5.3 Поставување на LCD екран
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" buttons to select setting programs, then press "ENTER" to confirm or "ESC" to exit.
The LCD settings allow configuration of various parameters, including output source priority, maximum charging current, AC input voltage range, battery type, auto-restart options, output voltage, output frequency, auto bypass, and various battery charging and equalization settings. Refer to the detailed tables in the PDF user manual for specific program numbers and options.
5.4 Setting for Lithium Battery
If using a lithium battery with the inverter, ensure it is a compatible type. There are two connectors on the lithium battery: an RS485 port for BMS communication and a power cable.
Lithium Battery Connection:
- Assemble battery terminals based on recommended cable and terminal size (refer to Lead-acid Battery connection section for details).
- Connect the RS485 port of the battery to the BMS (RS485) communication port of the inverter.
Lithium Battery Communication and Setting:
Ensure the BMS communication cable is connected between the battery and inverter. This cable facilitates information and signal exchange, allowing the inverter to:
- Повторно конфигурирајте ја јачината на полнењетоtage, charging current, and battery discharge cut-off voltage based on lithium battery parameters.
- Start or stop charging according to the lithium battery status.
The communication cable is typically included in the package. Ensure the lithium battery RS485 port connects pin-to-pin to the inverter's RS485 port. Refer to the PDF user manual for pin assignments.
Setting for PYLON US2000 Lithium Battery:
For PYLONTECH US2000 lithium batteries, configure the Dip Switches for baud rate and battery group address. Dip switch position 'OFF' means '0', and 'ON' means '1'. Dip 1 'ON' sets the baud rate to 9600. Dips 2, 3, and 4 are reserved for battery group address on the master battery.
Process of Install:
- Use the RS485 cable to connect the inverter and Lithium battery.
- Switch on the Lithium battery.
Setting for Lithium Battery without Communication:
If using a lithium battery without communication, obtain the battery's BMS specifications (Max charging voltage, Max charging current, Discharging protection voltage) and manually set the inverter's battery type to "User-Defined" (program 05). Then, set the C.V voltagд, лебдечко полнење волtage, and max charging current protection accordingly. It is recommended to complete these settings before turning on the inverter's output.
6. Одржување
6.1 Израмнување на батеријата
The equalization function helps reverse negative chemical effects like stratification and removes sulfate crystals that can reduce battery capacity. It is recommended to equalize batteries periodically.
How to Apply Equalization Function:
First, enable the battery equalization function in LCD setting program 33. Then, apply it by either:
- Поставување на интервалот за изедначување во програмата 37.
- Веднаш активирање на изедначувањето во програмата 39.
When to Equalize:
Во плови сtage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage.
Equalize Charging Time and Timeout:
During the Equalize stage, the controller charges the battery until it reaches the battery equalization voltage. Константен волуменtage regulation then maintains this voltage. The battery remains in this stage until the set battery equalized time expires. If the battery voltage не го достигнува волуменот на изедначувањеtage by the end of the equalized time, the charge controller will extend the time. If the battery voltage is still low after the equalized timeout, the controller will stop equalization and return to the float stage.
7 Смена на проблеми
This section provides guidance on common issues, fault codes, and warning indicators. For more detailed troubleshooting, refer to the comprehensive PDF user manual.
7.1 Fault Reference Codes
| Код за грешка | Дефект настан | Икона на LCD екранот |
|---|---|---|
| 01 | Претерана температура на инвертерскиот модул | 01 |
| 02 | Преку температура на DCDC модулот | 02 |
| 03 | Волумен на батеријаtage е премногу висока | 03 |
| 04 | Над температура на PV модулот | 04 |
| 05 | Излезен краток спој. | 05 |
| 06 | Излез волtagе премногу висока. | 06 |
| 07 | Истече времето за преоптоварување | 07 |
| 08 | Bus voltage е премногу висока | 08 |
| 09 | Мекиот старт на автобусот не успеа | 09 |
| 10 | PV над струја | 10 |
| 11 | PV над волtage | 11 |
| 12 | DCDC над струја | 12 |
| 13 | Преку струја или пренапон | 13 |
| 14 | Bus voltage е премногу ниско | 14 |
| 15 | Инвертерот не успеа (само-проверка) | 15 |
| 18 | Поместувањето на оперативната струја е превисоко | 18 |
| 19 | Поместувањето на струјата на инверторот е превисоко | 19 |
| 20 | Поместувањето на DC/DC струјата е превисоко | 20 |
| 21 | Поместувањето на струјата на PV е превисоко | 21 |
| 22 | Излез волtage е премногу ниско | 22 |
| 23 | Негативна моќност на инверторот | 23 |
7.2 Индикатори за предупредување
| Код за предупредување | Предупредувачки настан | Звучен аларм | Трепка икона |
|---|---|---|---|
| 02 | Температурата е превисока | Бип три пати секоја секунда | 02 |
| 04 | Слаба батерија | Бип еднаш во секунда | 04 |
| 07 | Преоптоварување | Бип еднаш на секои 0.5 секунди | 07 |
| 10 | Намалување на излезната моќност | Бип двапати на секои 3 секунди | 10 |
| 14 | Вентилаторот е блокиран | Никој | 14 |
| 15 | ФВ енергијата е мала | Бип двапати на секои 3 секунди | 15 |
| 19 | Комуникацијата со литиумска батерија е неуспешна | Бип еднаш на секои 0.5 секунди | 19 |
| 21 | Литиумска батерија со пренапон | Никој | 21 |
| E9 | Изедначување на батеријата | Никој | E9 |
| bP | Батеријата не е поврзана | Никој | bP |
8. Спецификации
The following tables provide detailed technical specifications for the SANDISOLAR SD-HYM-2430HW-US Solar Inverter.
| МОДЕЛ ИНВЕРТЕР | 3 KVA |
|---|---|
| Влез волуменtage Бранова форма | Синусоидален (корисна или генератор) |
| Номинален влез волtage | 120 Вак |
| Ниска загуба Voltage | 95Vac±7V (UPS); 70Vac±7V (Апарати) |
| Ниска повратна загуба Voltage | 100Vac±7V (UPS); 75Vac±7V (Апарати) |
| Високи загуби Voltage | 140Vac±7V |
| Враќање со голема загуба Voltage | 135Vac±7V |
| Максимален AC влезен волуменtage | 150 Вак |
| Номинална влезна фреквенција | 50 Hz / 60 Hz (автоматско откривање) |
| Ниска фреквенција на загуби | 40 ± 1Hz |
| Ниска фреквенција за враќање на загуби | 42 ± 1Hz |
| Висока фреквенција на загуби | 65 ± 1Hz |
| Висока фреквенција за враќање на загуби | 63 ± 1Hz |
| Заштита од краток спој на излезот | Режим на батерија: Електронски кола |
| Ефикасност (линиски режим) | >95% (Номинално оптоварување R, батерија целосно наполнета) |
| Време на трансфер | 10ms типични (UPS); Типични 20 ms (Апарати) |
| Намалување на излезната моќност: кога AC влез voltage паѓа на 95 V, излезната моќност ќе биде намалена. | ![]() |
| МОДЕЛ ИНВЕРТЕР | 3 KVA |
|---|---|
| Номинална излезна моќност | 3.0KVA/3.0KW |
| Излез Voltage Бранова форма | Чист синусен бран |
| Излез Voltagд Регулатива | 120Vac±5% |
| Излезна фреквенција | 50 Hz или 60 Hz |
| Врвна ефикасност | 94% |
| Пренапонски капацитет | 2* номинална моќност за 5 секунди |
| Номинален DC влезен волуменtage | 24 Vdc |
| Cold Start Voltage | 23.0 Vdc |
| Без оптоварување Потрошувачка на енергија | <55 W |
| Ниско DC предупредување Voltage (Just for AGM and Flooded) | @load < 20%: 22.0Vdc; @20% ≤ load < 50%: 21.4Vdc; @load ≥ 50%: 20.4Vdc |
| Ниско DC Warning Return Voltage (Just for AGM and Flooded) | @load < 20%: 23.0Vdc; @20% ≤ load < 50%: 22.4Vdc; @load ≥ 50%: 21.2Vdc |
| Ниско DC Cut-off Voltage (Just for AGM and Flooded) | @load < 20%: 21.0Vdc; @20% ≤ load < 50%: 20.4Vdc; @load ≥ 50%: 19.2Vdc |
| Комунален режим на полнење | 3 KVA |
|---|---|
| Max Charging Current (PV+AC) (@VI/P=230Vac) | 100Amp |
| Max Charging Current (AC) (@VI/P=230Vac) | 60Amp |
| Масовно полнење Voltage (Поплавена батерија) | 29.2 Vdc |
| Масовно полнење Voltage (AGM / гел батерија) | 28.2 Vdc |
| Пловечки полнење Voltage | 27 Vdc |
| Заштита од преполнување | 32 Vdc |
| Алгоритам за полнење | 3-Чекор |
| Solar Input Rated Power | 4000 W |
| Макс. PV Array Open Circuit Voltage | 500 Vdc |
| PV Array MPPT Voltagе опсег | 60Vdc~500Vdc |
| Макс. Влезна струја | 27 А |
| Max. Charging Current (PV) | 100 А |
| МОДЕЛ ИНВЕРТЕР | 3 KVA |
|---|---|
| Опсег на работна температура | -10°C до 50°C |
| Температура на складирање | -15°C до 60°C |
| Влажност | 5% до 95% релативна влажност (не кондензира) |
| Dimensions (D*W*H), mm | 312.4 × 350 × 114.5 |
| Нето тежина, кг | 8.5 |
| Комуникациски интерфејс | Dry contact + RS485 + WIFI |
| Заштита од навлегување | IP21 |
9. Wi-Fi Plug Pro Quick Installation Guideline
The inverter includes built-in WiFi for remote monitoring and control via the SmartESS App.
9.1 Installing the Wireless Antenna
Refer to the schematic diagram in the PDF user manual for instructions on removing and installing the wireless antenna.
9.2 Додадете даталогер
- Log in to your SmartESS account and click the Datalogger button. Tap the "+" button on the top-right corner of the datalogger page.
- Follow the prompts to enter the information and finish adding the datalogger. The PN number is located next to the machine appliance label. The initial password is 12345678.
9.3 Преземете ја АПП
- Scan the QR code provided in the PDF manual or search for "SmartESS" in your iPhone App Store or Android phone's app store to download the application.
- Open the APP, click the "Registration" button, and select "Mobile phone Registration" or "Email Registration".
- Вклучете Bluetooth или WiFi по потреба.
9.4 Bluetooth Connection to the Digital Collector
- Click the "Toolbox" in the app and select "BLE network" or "Wi-Fi network" as required.
- If you choose the Bluetooth distribution network, the app will automatically scan for nearby devices on the "Bluetooth Pairing" page. Find the PN corresponding to your digital collector and click "Connect".
9.5 Networking Settings
- Select the corresponding 2.4G WiFi network, fill in the password, and click "Start Connecting to the Network".

10. Гаранција и поддршка