SANDISOLAR SD-HYM-2430HW-US

SANDISOLAR 3KW 24V 110V/120V Solar Inverter User Manual

Model: SD-HYM-2430HW-US

Brand: SANDISOLAR

1. Вовед

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SANDISOLAR 3KW 24V 110V/120V Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

1.1 Производ надview

The SANDISOLAR SD-HYM-2430HW-US is an off-grid pure sine wave solar inverter designed for various applications, including power generation systems, household use, and PV roof installations. It features a built-in 100A MPPT solar charger and WiFi for remote monitoring.

SANDISOLAR 3KW 24V Solar Inverter with key specifications
Figure 1.1: SANDISOLAR 3KW 24V Solar Inverter highlighting 3KW 24V, 110VAC, 5000W Max PV Array Power, 100A Max Solar Charge Current, 500VDC Max PV Circuit Voltage, and Built-in WiFi.

1.2 Клучни карактеристики

  • Излез со чист синусен бран за чувствителна електроника.
  • Built-in MPPT 100A solar charger for efficient solar energy harvesting.
  • Max PV влезен волуменtage од 500Vdc.
  • Integrated WiFi for remote monitoring and control via the SmartESS App.
  • Capable of working without a battery.
  • Dual output for smart load management.
  • Detachable dust cover for protection in harsh environments.
  • Compatible with LiFePO4 batteries via RS485 communication.
  • Lithium battery activation function via PV or Utility.
  • Supports multiple output priorities: UTL (Utility), SOL (Solar), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery).
  • EQ (Equalization) function to optimize battery performance and extend lifecycle.
Diagram showing 100A MPPT technology and other inverter features
Figure 1.2: Visual representation of key inverter features including 100A MPPT, Pure Sine Wave, PV 60-500Vdc, Lithium Battery Activation, Anti-shock Design, Dual Outputs, WiFi, and RS485.

1.3 Апликативни сценарија

Images depicting various application scenarios for the solar inverter
Слика 1.3: Прamples of inverter applications including power generation systems, household use, PV roof installations, indoor areas, and farms.

2. Безбедносни предупредувања

ПРЕДУПРЕДУВАЊЕ: Опасност од удар

Инсталирањето мора да се изврши внимателно поради големата јачина на батеријатаtage во серија.

ВНИМАНИЕ!!

  • Do not place anything between the flat part of the inverter terminal. Otherwise, overheating may occur.
  • Не нанесувајте антиоксидантна супстанција на приклучоците пред да се поврзат цврсто.
  • Пред да го направите последното поврзување со еднонасочна струја или да го затворите прекинувачот/раскинувачот за еднонасочна струја, проверете дали позитивното (+) мора да биде поврзано со позитивно (+), а негативното (-) мора да биде поврзано со негативно (-).
  • ПОГОДЕН ЗА МОНТАЖА САМО НА БЕТОН ИЛИ ДРУГА НЕЗАПАЛИВИ ПОВРШИНИ.

3. Отпакување и проверка

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:

Видео 3.1: Распакување и иницијал одозгораview of the SANDISOLAR solar inverter.

4. Инсталација

4.1 Подготовка

Before connecting all wirings, please remove the bottom cover by unscrewing two screws.

4.2 Монтирање на единицата

Consider the following points when selecting the installation location:

  1. Не монтирајте го инверторот на запаливи градежни материјали.
  2. Монтирајте на цврста површина.
  3. Инсталирајте го овој инвертер во висина на очите за да можете постојано да го читате LCD екранот.
  4. Температурата на околината треба да биде помеѓу 0°C и 55°C за да се обезбеди оптимална работа.
  5. The recommended installation position is vertically on the wall.
  6. Ensure sufficient clearance around the unit for heat dissipation and wire routing, as shown in the diagram below.
Product dimensions and mounting clearances
Figure 4.1: Product dimensions (350mm H, 313mm W, 115mm D) and recommended clearances for mounting.

Install the unit by screwing three screws. It's recommended to use M4 or M5 screws.

4.3 Поврзување на батеријата

ВНИМАНИЕ:

For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the typical amperage in the table below for required fuse or breaker size.

ПРЕДУПРЕДУВАЊЕ!

All wiring must be performed by qualified personnel. It is critical for system safety and efficient operation to use appropriate cables for battery connection. To reduce risk of injury, use the proper recommended cable and terminals.

Recommended Battery Cable & Terminal Size (3KVA Model)
МоделМаксимум AmpбесКапацитет на батеријатаГолемина на жицаКабел mm²Terminal Size L(mm)Terminal Size W(mm)Terminal Size D(mm)Вредност на вртежниот момент
3 KVA137 А200 АХ2AWG353715.36.44~6 Nm

Следете ги овие чекори за да ја поврзете батеријата:

  1. Create battery positive and negative cables according to the recommended specifications.
  2. Поврзете ги сите батерии по потреба.
  3. Insert battery cables flatly into the inverter's battery connector and ensure bolts are tightened with a torque of 4~6 Nm. Verify correct polarity at both the battery and the inverter/charger.

4.4 Влез/излезен приклучок за наизменична струја

ВНИМАНИЕ!!

Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. The recommended AC breaker specification is 50A. There are two terminal blocks marked “IN” and “OUT”; do NOT mis-connect input and output connectors.

ПРЕДУПРЕДУВАЊЕ!

All wiring must be performed by qualified personnel. It is crucial for system safety and efficient operation to use appropriate cables for AC input connection. To reduce risk of injury, use the proper recommended cable size.

Suggested Cable Requirement for AC Wires (3KVA Model)
МоделМерачВредност на вртежниот момент
3 KVA10AWG1.4~1.6 Nm

Follow these steps to connect AC input/output:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (➔Ground (yellow-green)) first.
  4. Insert AC output wires according to the polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (➔Ground (yellow-green)) first.
  5. Проверете дали сите жици се безбедно поврзани.

ВНИМАНИЕ: Важно

Ensure AC wires are connected with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuiting when inverters operate in parallel. Appliances like air conditioners require 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation.

4.5 PV поврзување

ВНИМАНИЕ:

Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

ПРЕДУПРЕДУВАЊЕ!

All wiring must be performed by qualified personnel. It is very important for system safety and efficient operation to use appropriate cables for PV module connection. To reduce risk of injury, use the proper recommended cable size.

Recommended PV Cable & Terminal Size (3KVA Model)
МоделТипично AmpбесГолемина на кабелВртежен момент
3 KVA27 А10 AWG1.4~1.6 Nm

Избор на PV модул:

When selecting PV modules, consider these parameters:

  1. Отвореното коло Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage на инверторот.
  2. Отвореното коло Voltage (Voc) of PV modules should be higher than the min. battery voltage.
Solar Charging Mode Specifications (3KVA Model)
МОДЕЛ ИНВЕРТЕР3 KVA
Макс. PV Array Open Circuit Voltage500 VDC
PV Array MPPT Voltagе опсег60VDC~500VDC
Макс. PV ВЛЕЗНА СТРУЈА27 А

Follow these steps for PV module wire connection:

  1. Remove 6mm of insulation sleeve for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) of PV input connector, and negative pole (-) to negative pole (-) of PV input connector.
  3. Проверете дали сите жици се безбедно поврзани.

4.6 Завршно собрание

Откако ќе ги поврзете сите жици, вратете го долниот капак со навртување на двата завртки назад на место.

Diagram showing solar panels connected to the inverter and battery, powering household loads.
Figure 4.2: System connection diagram illustrating PV panels, inverter, battery, and various household loads.

5. Операција

5.1 ВКЛУЧУВАЊЕ/ИСКЛУЧУВАЊЕ

Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.

Страна view of the inverter showing the power on/off switch and dry contact port.
Слика 5.1: Страна view of the inverter, indicating the Power On/Off switch (14) and Dry contact port (13).

5.2 Панел за работа и приказ

The front panel of the inverter includes an LCD display, three indicators, and four function keys, providing operating status and input/output power information.

Front panel of the inverter with LCD display, status indicators, and function buttons.
Figure 5.2: Front panel of the inverter, detailing the LCD Display (1), Status Indicator (2), Charging Indicator (3), Fault Indicator (4), and Function Buttons (5).
Rear panel of the inverter showing various connection ports.
Figure 5.3: Rear panel of the inverter, detailing Battery Input (6), RS485 Communication Port (7), Grounding (8), WiFi Antenna Port (9), AC Input (10), AC Output (11), and PV Input (12).
Пораки на LED индикаторот
LED индикаторБојаПораки
AC/INVЗеленаSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGЗеленаSolid On: Battery is fully charged.
Flashing: Battery is charging.
ВИНАЦрвеноSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.
Функциски копчиња Опис
Функциски клучОпис
ESCЗа да излезете од режимот на поставување.
UPTo go to previous selection.
ДОЛУTo go to next selection.
ENTERTo confirm the selection in setting mode or enter setting mode.

5.3 Поставување на LCD екран

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" buttons to select setting programs, then press "ENTER" to confirm or "ESC" to exit.

The LCD settings allow configuration of various parameters, including output source priority, maximum charging current, AC input voltage range, battery type, auto-restart options, output voltage, output frequency, auto bypass, and various battery charging and equalization settings. Refer to the detailed tables in the PDF user manual for specific program numbers and options.

5.4 Setting for Lithium Battery

If using a lithium battery with the inverter, ensure it is a compatible type. There are two connectors on the lithium battery: an RS485 port for BMS communication and a power cable.

Lithium Battery Connection:

  1. Assemble battery terminals based on recommended cable and terminal size (refer to Lead-acid Battery connection section for details).
  2. Connect the RS485 port of the battery to the BMS (RS485) communication port of the inverter.

Lithium Battery Communication and Setting:

Ensure the BMS communication cable is connected between the battery and inverter. This cable facilitates information and signal exchange, allowing the inverter to:

  • Повторно конфигурирајте ја јачината на полнењетоtage, charging current, and battery discharge cut-off voltage based on lithium battery parameters.
  • Start or stop charging according to the lithium battery status.

The communication cable is typically included in the package. Ensure the lithium battery RS485 port connects pin-to-pin to the inverter's RS485 port. Refer to the PDF user manual for pin assignments.

Setting for PYLON US2000 Lithium Battery:

For PYLONTECH US2000 lithium batteries, configure the Dip Switches for baud rate and battery group address. Dip switch position 'OFF' means '0', and 'ON' means '1'. Dip 1 'ON' sets the baud rate to 9600. Dips 2, 3, and 4 are reserved for battery group address on the master battery.

Process of Install:

  1. Use the RS485 cable to connect the inverter and Lithium battery.
  2. Switch on the Lithium battery.

Setting for Lithium Battery without Communication:

If using a lithium battery without communication, obtain the battery's BMS specifications (Max charging voltage, Max charging current, Discharging protection voltage) and manually set the inverter's battery type to "User-Defined" (program 05). Then, set the C.V voltagд, лебдечко полнење волtage, and max charging current protection accordingly. It is recommended to complete these settings before turning on the inverter's output.

6. Одржување

6.1 Израмнување на батеријата

The equalization function helps reverse negative chemical effects like stratification and removes sulfate crystals that can reduce battery capacity. It is recommended to equalize batteries periodically.

How to Apply Equalization Function:

First, enable the battery equalization function in LCD setting program 33. Then, apply it by either:

  1. Поставување на интервалот за изедначување во програмата 37.
  2. Веднаш активирање на изедначувањето во програмата 39.

When to Equalize:

Во плови сtage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage.

Equalize Charging Time and Timeout:

During the Equalize stage, the controller charges the battery until it reaches the battery equalization voltage. Константен волуменtage regulation then maintains this voltage. The battery remains in this stage until the set battery equalized time expires. If the battery voltage не го достигнува волуменот на изедначувањеtage by the end of the equalized time, the charge controller will extend the time. If the battery voltage is still low after the equalized timeout, the controller will stop equalization and return to the float stage.

7 Смена на проблеми

This section provides guidance on common issues, fault codes, and warning indicators. For more detailed troubleshooting, refer to the comprehensive PDF user manual.

7.1 Fault Reference Codes

Fault Codes and Events
Код за грешкаДефект настанИкона на LCD екранот
01Претерана температура на инвертерскиот модул01
02Преку температура на DCDC модулот02
03Волумен на батеријаtage е премногу висока03
04Над температура на PV модулот04
05Излезен краток спој.05
06Излез волtagе премногу висока.06
07Истече времето за преоптоварување07
08Bus voltage е премногу висока08
09Мекиот старт на автобусот не успеа09
10PV над струја10
11PV над волtage11
12DCDC над струја12
13Преку струја или пренапон13
14Bus voltage е премногу ниско14
15Инвертерот не успеа (само-проверка)15
18Поместувањето на оперативната струја е превисоко18
19Поместувањето на струјата на инверторот е превисоко19
20Поместувањето на DC/DC струјата е превисоко20
21Поместувањето на струјата на PV е превисоко21
22Излез волtage е премногу ниско22
23Негативна моќност на инверторот23

7.2 Индикатори за предупредување

Warning Codes and Events
Код за предупредувањеПредупредувачки настанЗвучен алармТрепка икона
02Температурата е превисокаБип три пати секоја секунда02
04Слаба батеријаБип еднаш во секунда04
07ПреоптоварувањеБип еднаш на секои 0.5 секунди07
10Намалување на излезната моќностБип двапати на секои 3 секунди10
14Вентилаторот е блокиранНикој14
15ФВ енергијата е малаБип двапати на секои 3 секунди15
19Комуникацијата со литиумска батерија е неуспешнаБип еднаш на секои 0.5 секунди19
21Литиумска батерија со пренапонНикој21
E9Изедначување на батеријатаНикојE9
bPБатеријата не е поврзанаНикојbP

8. Спецификации

The following tables provide detailed technical specifications for the SANDISOLAR SD-HYM-2430HW-US Solar Inverter.

Табела 8.1: Спецификации за линиски режим
МОДЕЛ ИНВЕРТЕР3 KVA
Влез волуменtage Бранова формаСинусоидален (корисна или генератор)
Номинален влез волtage120 Вак
Ниска загуба Voltage95Vac±7V (UPS); 70Vac±7V (Апарати)
Ниска повратна загуба Voltage100Vac±7V (UPS); 75Vac±7V (Апарати)
Високи загуби Voltage140Vac±7V
Враќање со голема загуба Voltage135Vac±7V
Максимален AC влезен волуменtage150 Вак
Номинална влезна фреквенција50 Hz / 60 Hz (автоматско откривање)
Ниска фреквенција на загуби40 ± 1Hz
Ниска фреквенција за враќање на загуби42 ± 1Hz
Висока фреквенција на загуби65 ± 1Hz
Висока фреквенција за враќање на загуби63 ± 1Hz
Заштита од краток спој на излезотРежим на батерија: Електронски кола
Ефикасност (линиски режим)>95% (Номинално оптоварување R, батерија целосно наполнета)
Време на трансфер10ms типични (UPS); Типични 20 ms (Апарати)
Намалување на излезната моќност: кога AC влез voltage паѓа на 95 V, излезната моќност ќе биде намалена.Output power derating curve
Табела 8.2: Спецификации за режимот на инвертер
МОДЕЛ ИНВЕРТЕР3 KVA
Номинална излезна моќност3.0KVA/3.0KW
Излез Voltage Бранова формаЧист синусен бран
Излез Voltagд Регулатива120Vac±5%
Излезна фреквенција50 Hz или 60 Hz
Врвна ефикасност94%
Пренапонски капацитет2* номинална моќност за 5 секунди
Номинален DC влезен волуменtage24 Vdc
Cold Start Voltage23.0 Vdc
Без оптоварување Потрошувачка на енергија<55 W
Ниско DC предупредување Voltage (Just for AGM and Flooded)@load < 20%: 22.0Vdc; @20% ≤ load < 50%: 21.4Vdc; @load ≥ 50%: 20.4Vdc
Ниско DC Warning Return Voltage (Just for AGM and Flooded)@load < 20%: 23.0Vdc; @20% ≤ load < 50%: 22.4Vdc; @load ≥ 50%: 21.2Vdc
Ниско DC Cut-off Voltage (Just for AGM and Flooded)@load < 20%: 21.0Vdc; @20% ≤ load < 50%: 20.4Vdc; @load ≥ 50%: 19.2Vdc
Табела 8.3: Спецификации за режим на полнење
Комунален режим на полнење3 KVA
Max Charging Current (PV+AC) (@VI/P=230Vac)100Amp
Max Charging Current (AC) (@VI/P=230Vac)60Amp
Масовно полнење Voltage (Поплавена батерија)29.2 Vdc
Масовно полнење Voltage (AGM / гел батерија)28.2 Vdc
Пловечки полнење Voltage27 Vdc
Заштита од преполнување32 Vdc
Алгоритам за полнење3-Чекор
Solar Input Rated Power4000 W
Макс. PV Array Open Circuit Voltage500 Vdc
PV Array MPPT Voltagе опсег60Vdc~500Vdc
Макс. Влезна струја27 А
Max. Charging Current (PV)100 А
Табела 8.4: Општи спецификации
МОДЕЛ ИНВЕРТЕР3 KVA
Опсег на работна температура-10°C до 50°C
Температура на складирање-15°C до 60°C
Влажност5% до 95% релативна влажност (не кондензира)
Dimensions (D*W*H), mm312.4 × 350 × 114.5
Нето тежина, кг8.5
Комуникациски интерфејсDry contact + RS485 + WIFI
Заштита од навлегувањеIP21

9. Wi-Fi Plug Pro Quick Installation Guideline

The inverter includes built-in WiFi for remote monitoring and control via the SmartESS App.

9.1 Installing the Wireless Antenna

Refer to the schematic diagram in the PDF user manual for instructions on removing and installing the wireless antenna.

9.2 Додадете даталогер

  1. Log in to your SmartESS account and click the Datalogger button. Tap the "+" button on the top-right corner of the datalogger page.
  2. Follow the prompts to enter the information and finish adding the datalogger. The PN number is located next to the machine appliance label. The initial password is 12345678.

9.3 Преземете ја АПП

  1. Scan the QR code provided in the PDF manual or search for "SmartESS" in your iPhone App Store or Android phone's app store to download the application.
  2. Open the APP, click the "Registration" button, and select "Mobile phone Registration" or "Email Registration".
  3. Вклучете Bluetooth или WiFi по потреба.

9.4 Bluetooth Connection to the Digital Collector

  1. Click the "Toolbox" in the app and select "BLE network" or "Wi-Fi network" as required.
  2. If you choose the Bluetooth distribution network, the app will automatically scan for nearby devices on the "Bluetooth Pairing" page. Find the PN corresponding to your digital collector and click "Connect".

9.5 Networking Settings

  1. Select the corresponding 2.4G WiFi network, fill in the password, and click "Start Connecting to the Network".
SmartESS App interface for monitoring and control
Figure 9.1: SmartESS App interface for monitoring and controlling the inverter.

10. Гаранција и поддршка

The SANDISOLAR SD-HYM-2430HW-US Solar Inverter comes with a 2-year warranty from the store. For any issues or support, please contact the seller directly.

Информации за гаранција и сервис
Figure 10.1: Warranty and service details, including a 2-year warranty.
Documents - SANDISOLAR – SD-HYM-2430HW-US