AmScope B120C

AmScope 40X-2500X LED Compound Binocular Laboratory Microscope

Модел: B120C

Бренд: AmScope

Вовед

The AmScope B120C binocular compound microscope is engineered for educational, clinical, and laboratory applications. It is an ideal instrument for students and professionals in medical and biological fields. This microscope features a professional Siedentopf binocular head, a double-layer mechanical stage, coaxial coarse and fine focusing, and LED illumination. It offers six magnification settings ranging from 40x to 2500x, making it suitable for detailed biological, pharmaceutical, and bacteriological research.

This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your AmScope B120C microscope to ensure optimal performance and longevity.

Поставување и склопување

Upon unboxing, carefully remove all components from the packaging. Ensure all parts are present and undamaged before proceeding with assembly.

AmScope B120C Microscope fully assembled with sample view

Figure 1: Fully assembled AmScope B120C microscope with an example of a blood cell sample under observation.

Почетни чекори за поставување:

  1. Отпакување: Gently remove the microscope body, binocular head, eyepieces, objectives, and power cord from their protective packaging.
  2. Attaching the Binocular Head: Loosen the head locking screw on the top of the microscope body. Carefully insert the binocular head into the top port, ensuring it is fully seated. Tighten the locking screw to secure the head.
  3. Вметнување окулари: Insert the WF10X and WF25X widefield eyepieces into the eyepiece tubes of the binocular head.
  4. Installing Objectives: Rotate the revolving nosepiece to expose the empty objective ports. Screw in the 4x, 10x, 40x (S), and 100x (S, oil) achromatic objectives into the nosepiece in ascending order of magnification.
  5. Поврзување за напојување: Connect the power cord to the microscope's power input and then to a 240 Volt AC power outlet. Ensure the power switch is in the OFF position before connecting.
  6. Прилагодување на меѓупупиларното растојание: While looking through the eyepieces, adjust the distance between the eyepiece tubes by moving them closer or further apart until a single, clear circular field of view се забележува.
  7. Прилагодување на диоптрија: If one eye is dominant or has different vision, use the diopter adjustment ring on one of the eyepiece tubes to fine-tune focus for that eye after focusing with the other eye.

Упатства за работа

Binocular Head Rotation:

The Siedentopf binocular head can be rotated 360 degrees and is inclined at 30 degrees for comfortable viewing, reducing neck strain during prolonged use.

Binocular head rotation and inclination diagram

Figure 2: The binocular head offers 360-degree rotation and a 30-degree inclination for ergonomic viewинг.

Поставки за зголемување:

The microscope provides six widefield magnification settings by combining the WF10X and WF25X eyepieces with the 4x, 10x, 40x, and 100x objectives:

Microscope objectives and eyepieces with magnification exampлес

Figure 3: Illustration of various magnification levels achievable with the included objectives and eyepieces.

Механички Сtage and Focusing:

The double-layer mechanical stage allows for smooth and precise movement of specimen slides. Use the coaxial coarse and fine focus knobs located on both sides of the microscope for accurate focusing.

Механички сtage and focus knobs diagram

Figure 4: The mechanical stage provides precise slide positioning, controlled by separate coarse and fine focus knobs.

Систем за LED осветлување:

The microscope features powerful LED transmitted illumination with variable intensity. The light source is daylight balanced to produce natural colors for imaging, improving contrast and resolution.

LED illumination system diagram

Figure 5: The LED sub-stage lighting provides cool, energy-efficient illumination for clear specimen viewинг.

Person using AmScope B120C microscope

Figure 6: A user observing a specimen through the AmScope B120C microscope.

Микроскопски view of pink biological tissue

Слика 7: Прample of a biological tissue sample as seen through the microscope.

Микроскопски view of plant cells

Слика 8: Прample of plant cells observed under the microscope.

Одржување и нега

Proper maintenance ensures the longevity and optimal performance of your microscope.

Решавање проблеми

This section addresses common issues you might encounter with your microscope.

ПроблемМожна причинаРешение
Без осветлувањеPower cord disconnected; power switch off; intensity knob set to minimum.Check power connection; turn on power switch; increase intensity.
Заматена слика или надвор од фокусIncorrect focus adjustment; objective not fully engaged; slide upside down.Adjust coarse and fine focus; rotate nosepiece until objective clicks into place; ensure slide cover slip is facing up.
Eyepiece does not stay in positionEyepiece not fully inserted or locking mechanism loose.Ensure eyepiece is fully seated in the tube. If a locking screw is present, tighten it gently.
UK plug provided without adapterIncorrect regional power plug.An adapter for your region (e.g., Schuko for EU) should be included. If not, contact customer support.

Спецификации

КарактеристикаДетал
МоделB120C
БрендAmScope
Microscope TypeCompound Binocular
ОкулариWF10X, WF25X Widefield
Цели4x, 10x, 40x (S), 100x (S, oil) Achromatic DIN
Опсег на зголемување40x - 2500x
ГлаваSiedentopf Binocular, 30-degree inclined, 360-degree rotatable
Меѓупупиларно растојаниеПрилагодлив
Прилагодување на диоптријаOn left eyepiece tube
НосникRevolving, Quadruple
StageDouble-layer Mechanical Stage, Stain-resistant
ФокусирањеCoaxial Coarse and Fine Focus, with tension control and stagе стоп
ОсветлувањеLED Transmitted, Variable Intensity
КондензаторNA1.25 Abbe Condenser with Iris Diaphragm and Filters, Rack and Pinion Adjustment
Напојување240 Volt AC, Battery Power (Type: Battery Power Supply)
МатеријалМетал
Димензии45.6 x 31.6 x 24 cm
Тежина4.46 кг

Гаранција и поддршка

For warranty information, technical support, or any inquiries regarding your AmScope B120C microscope, please contact the seller, AmScope Global, directly through the platform where the purchase was made. Ensure you have your purchase details and model number (B120C) ready for faster assistance.

You can typically find seller contact information on your order details page or by visiting the AmScope brand store on Amazon.

Visit the AmScope Store on Amazon

Поврзани документи - B120C

Предview AmScope 120 Series Microscope User Manual
Comprehensive user manual for the AmScope 120 Series microscopes (B120 and T120), covering setup, operation, specifications, and troubleshooting.
Предview AmScope 120 Series Microscope User Manual
Comprehensive user manual for the AmScope 120 Series microscopes, covering setup, operation, specifications, and troubleshooting for models like B120 and T120.
Предview AmScope M150 Series Microscope User Manual
User manual for the AmScope M150 Series microscopes, covering setup, operation, maintenance, specifications, and troubleshooting.
Предview Упатство за употреба на AmScope DM150-W Full HD дигитален сложен микроскоп
Сеопфатно упатство за корисникот за дигиталниот сложен микроскоп AmScope DM150-W Full HD, кое опфаќа поставување, работа, безбедност и одржување за оптимална употреба.
Предview AmScope PM240 Series Stereo Microscope User Manual
User manual for the AmScope PM240 Series stereo microscopes, covering setup, operation, specifications, and troubleshooting for binocular and trinocular models.
Предview AmScope 490 Series Compound Microscope Operator's Manual
This operator's manual provides comprehensive instructions for the AmScope 490 Series Compound Microscope, covering setup, operation, maintenance, and troubleshooting for optimal use.