Prity AW16

Prity AW16 Corner MultiFuel Wood Stove Insert User Manual

1. Производот завршиview

The Prity AW16 is a wood-burning fireplace insert designed for corner placement, featuring a water jacket for integration into a central heating system. It is equipped with heat-resistant ceramic glass, a cast iron grate, and wooden handles for safe operation. Control over air supply and flame intensity is managed via front and smoke dampг.

Prity AW16 Wood Stove Insert with fire burning

Image 1.1: The Prity AW16 wood stove insert with a fire burning in the combustion chamber.

2. Важни безбедносни информации

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, injury, or death.

  • Секогаш обезбедете соодветна вентилација за време на работата.
  • Only use approved fuel types (dry wood, wood briquettes).
  • Keep children and pets away from the hot surfaces of the stove.
  • Не чувајте запаливи материјали во близина на шпоретот.
  • Regularly inspect the chimney and flue for blockages or damage.
  • Ensure minimum clearances to combustible materials are strictly observed:
    • Заден дел: 400 mm
    • Left and Right Sides: 400 mm
    • Таван: 600 mm
    • Front: 800 mm (within the entire radiation area of the glass)
    • Floor: 0 mm (if non-combustible)

3. Водич за инсталација

3.1 Поставување

The Prity AW16 is designed as an insert for corner installations. Ensure the chosen location can support the stove's weight and meets all safety clearance requirements.

3.2 димензии и дозволи

Accurate measurements are crucial for safe and effective installation.

  • Total Dimensions (L x W x H): 1010 x 690 x 730 mm
  • Combustion Chamber Dimensions (L x W x H): 880 x 550 x 370 mm
  • Тежина: 125 кг
  • Flue Pipe Diameter: 200 mm
Prity AW16 Wood Stove Insert installed in a living room corner

Image 3.1: The Prity AW16 wood stove insert integrated into a corner fireplace setting in a living room.

3.3 Connection to Central Heating

This model includes a water jacket for connection to a central heating system. Professional installation by a qualified technician is highly recommended for this component to ensure proper function and safety. The water jacket volume is 34 liters.

4. Упатства за работа

4.1 Тип на гориво

The Prity AW16 is designed for burning solid fuels, specifically dry wood or wood briquettes. Do not use liquid fuels, trash, or treated wood, as this can damage the stove and pose a safety hazard.

4.2 Loading Fuel

Open the main door using the wooden handle. Place dry wood or briquettes onto the cast iron grate. Avoid overfilling the combustion chamber. Close the door securely before igniting or adjusting air controls.

4.3 Контрола на воздухот

The stove features a front damper to control the primary air supply to the combustion chamber. Adjust this damper to regulate the intensity of the fire. For initial ignition, keep the damper fully open. Once the fire is established, you can reduce the air supply to achieve a slower burn.

4.4 Flame Intensity

A smoke damper is provided to further adjust the flame intensity and control the rate at which exhaust gases leave the combustion chamber. Use this in conjunction with the front air damper to optimize burning efficiency and heat output.

5. Одржување

5.1 Чистење

  • Отстранување на пепел: Regularly remove ash from the ash pan beneath the cast iron grate. Ensure the stove is completely cool before handling ash.
  • Чистење на стакло: The ceramic glass can be cleaned when cool using a specialized fireplace glass cleaner or a damp cloth dipped in ash.
  • Flue and Chimney: Have your flue and chimney inspected and cleaned by a qualified professional at least once a year, or more frequently depending on usage.

5.2 Инспекција

Periodically inspect the stove for any signs of wear or damage, including:

  • Cracks in the ceramic glass.
  • Damage to the door seals.
  • Loose or damaged components (dampers, handles).
  • Corrosion or damage to the water jacket connections.

Any damaged parts should be replaced immediately by a qualified technician.

6 Смена на проблеми

Овој дел дава општи упатства за вообичаени проблеми. За сложени проблеми, консултирајте се со квалификуван техничар.

  • Poor Draft/Smoke Backflow: Check for chimney blockages, ensure dampers are open, and verify proper chimney height and insulation.
  • Ниска излезна топлина: Ensure you are using dry, seasoned wood. Check air damper settings and ensure the combustion chamber is not overfilled. Verify water jacket connections are functioning correctly if connected to central heating.
  • Excessive Burn Rate: Adjust the front air damper and smoke damper to reduce air supply. Ensure door seals are intact.

7. Технички спецификации

СпецификацијаВредност
Број на моделAW16
БрендПрити
Вкупни димензии (Д x Ш x В)1010 x 690 x 730 mm
Combustion Chamber Dimensions (L x W x H)880 x 550 x 370 mm
Тежина125 кг
Nominal Heating Power (Total)16 + 5 kW (21 kW)
Water Heating Output16 kW
Room Heating Output5 kW
Water Jacket Volume34 литри
Дијаметар на цевката за чад200 мм
Heated Surface AreaПрибл. 119 m²
Капацитет за греењеApprox. 323 m³
МатеријалGlass, Wood, Ceramic, Cast Iron
Енергетска класаA
Maximum Working Pressure (Water)1.25 бари
Efficiency (Nominal Heat Output)79.4%
ASINB06XH1PC8T
Product Identifier (from image)3800215095108
Prity AW16 Energy Efficiency Label

Image 7.1: Energy efficiency label for the Prity AW16, showing an A rating and heat outputs.

Prity AW16 Declaration of Performance (English)

Image 7.2: Declaration of Performance for the Prity AW16, detailing essential characteristics and compliance with EU regulations.

8. Гаранција и поддршка

Information regarding specific warranty terms and customer support contacts was not available in the provided product data. Please refer to your purchase documentation or contact the retailer for details on warranty coverage and technical assistance.

Поврзани документи - AW16

Предview Prity Fireplaces and Fireboxes: Installation and Operation Manual
Comprehensive guide for Prity fireplaces and fireboxes, covering technical specifications, installation procedures, operation instructions, maintenance, and warranty information. Ensure safe and efficient use of your Prity heating appliance.
Предview Prity Boilers: Technical Description, Installation, and Operation Manual
Comprehensive guide for Prity residential boilers, covering technical specifications, installation procedures, operation instructions, maintenance, and troubleshooting for solid fuel and pellet models.
Предview Product Similarity Declaration for Shenzhen Aiweile Intelligent Watch Models
Declaration by Shenzhen Aiweile Technology Co., Ltd. confirming product similarity across various Intelligent Watch models (AW12, AW1, AW2, etc.), detailing shared hardware, software, and mechanical designs.