Вовед
This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Информации за безбедност
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Овој производ е дизајниран само за внатрешна употреба.
- Не поврзувајте повеќе напојувачки ленти заедно.
- Осигурајте се дека разводната лента е правилно заземјена.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Да се чува подалеку од вода и средини со висока влажност.
- Ensure proper ventilation when installed in a rack.
Содржина на пакетот
Проверете дали сите предмети се присутни и неоштетени:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Упатство за употреба
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Производот завршиview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Слика: Целосен view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Клучни карактеристики:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Слика: Детална view of the angled Schuko power plug, which connects the power strip to the main power source.
Поставување и инсталација
- Распакувајте го разводникот: Внимателно извадете го разводникот од пакувањето. Проверете дали има знаци на оштетување.
- Изберете локација за монтирање: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Поврзете се со извор на напојување: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Поврзете ги уредите: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Image: A partial view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Операција
- Вклучување: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Заштита од преоптоварување: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Исклучено: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Одржување
- Чистење: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Инспекција: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Вентилација: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Решавање проблеми
| Проблем | Можна причина | Решение |
|---|---|---|
| Нема струја во штекерите. | Се прекина прекинувачот. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| Нема струја во штекерите. | Разводникот не е вклучен во штекер. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Ако проблемот продолжи откако ќе се обидете со овие решенија, контактирајте ја корисничката поддршка.
Спецификации
- Модел: I-CASE STRIP-12SH
- Бренд: Techly Professional
- Продажни места: 12 x Schuko (Type F) 45° angled with earth
- Влезен приклучок: Angled Schuko (Type F)
- Кабел: H05VV-F 3G 2.5 mm²
- Должина на кабелот: 3 метри
- Електричен рејтинг: 16 A, 250 V AC
- Максимален капацитет на носивост: 3.5 kW
- Димензии (Д x Ш x В): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Тежина: 1795 грама
- Материјал: Aluminum (body), Black (finish)
- Специјална карактеристика: Mountable (vertical rack installation)
- Сертификати: CE, WEEE
Информации за гаранцијата
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Политика за враќање: The buybox winner indicates a 30-day return policy (refund/replacement).
Поддршка за корисници
For technical assistance or further inquiries, please visit the official Techly webсајт или контактирајте со вашиот продавач на мало.
Производител: TECHLY PROFESSIONAL
Webсајт: www.techly.com (Hypothetical link, as not provided in JSON)