Вовед
This manual provides essential information for the safe and efficient operation of your Nedis UPSD2000VBK Uninterruptible Power Supply. Please read these instructions carefully before installation and use, and retain them for future reference. This UPS is designed to provide backup power and protect your electronic devices from power outages, surges, and fluctuations.
Инструкции за безбедност
- Само за внатрешна употреба: This UPS is designed for indoor use in a controlled environment. Do not expose it to rain, snow, or direct sunlight.
- Вентилација: Ensure adequate ventilation around the UPS. Do not block ventilation openings. Maintain at least 20 cm of clearance from walls or other obstructions.
- Извор на енергија: Connect the UPS to a properly grounded AC power outlet. Do not remove the grounding prong.
- Преоптоварување: Do not overload the UPS. The total power consumption of connected equipment must not exceed the UPS's rated capacity (1200 W).
- Безбедност на батеријата: The UPS contains internal batteries. Do not attempt to open the UPS casing or service the batteries yourself. Refer all servicing to qualified personnel.
- Контакт со течност: Avoid placing liquids on or near the UPS. In case of accidental spillage, immediately disconnect the UPS from the power source and contact support.
- Итно исклучување: Ensure the AC power outlet for the UPS is easily accessible for quick disconnection in an emergency.
Производот завршиview
The Nedis UPSD2000VBK is a compact and efficient uninterruptible power supply. Familiarize yourself with its components before proceeding with installation.

Слика 1: Предни и странични view of the Nedis UPSD2000VBK. This image displays the main power button and the vertical strip of LED indicators on the front panel, along with ventilation grilles on the side.

Слика 2: Заден дел view of the Nedis UPSD2000VBK. This image highlights the four power outlets, the USB communication port, and the RJ45 network protection ports (IN/OUT), along with the main power input and cooling fan.
Клучни компоненти:
- Преден панел: Power button, LED status indicators (AC mode, battery mode, fault, battery level).
- Заден панел: AC input, 4 x Schuko output sockets, USB communication port, RJ45 network protection ports (IN/OUT).
- Внатрешна: Sealed lead-acid batteries, inverter, charger, control circuitry.
Поставување
1. Отпакување
- Внимателно извадете го UPS-от од пакувањето.
- Проверете го уредот за евентуални оштетувања при транспортот. Доколку се открие оштетување, не го користете уредот и контактирајте го вашиот продавач.
2 Поставување
- Place the UPS on a flat, stable surface in a well-ventilated area.
- Avoid locations with excessive dust, humidity, or extreme temperatures.
- Погрижете се температурата на околината да биде помеѓу 0°C и 40°C (32°F и 104°F).
3. Поврзување на уредите
- Поврзете го кабелот за напојување на UPS-от со заземјен ѕиден штекер.
- Plug your computer, monitor, and other critical devices into the output sockets on the rear of the UPS. Ensure the total load does not exceed 1200 W.
- Изборно: Connect a USB cable from the UPS to your computer for monitoring software functionality (software not included, typically available from manufacturer's webстраница).
- Изборно: Connect network cables through the RJ45 IN/OUT ports to protect your network devices from surges.
4. Почетно полнење
For optimal performance, charge the UPS for at least 8 hours before initial use. Leave the UPS connected to the AC power outlet with no load connected during this period.
Оперативни
1. Вклучување/исклучување
- За да се вклучи: Притиснете го и држете го копчето за вклучување на предната плоча приближно 3 секунди додека не слушнете звучен сигнал и индикаторите не светнат.
- Да се исклучи: Press and hold the power button for approximately 3 seconds until you hear a beep and the indicators turn off.
2. Разбирање на индикаторите и алармите
The front panel features LED indicators and an audible alarm to communicate the UPS status:
- AC Mode (Green LED): Solid green indicates the UPS is operating on utility power and charging the battery.
- Battery Mode (Yellow LED): Flashing yellow indicates the UPS is operating on battery power. An audible alarm will sound periodically.
- Fault (Red LED): Solid red indicates a fault condition. Refer to the troubleshooting section. An audible alarm may sound continuously.
- Индикатори за нивото на батеријата: A series of LEDs typically indicates the remaining battery capacity.
3. Battery Mode Operation
When utility power fails, the UPS automatically switches to battery mode, providing power to connected devices. The duration of battery backup depends on the load connected. During battery mode, save your work and shut down your equipment properly to prevent data loss.
Одржување
1. Нега на батерии
- To maximize battery life, keep the UPS connected to an AC outlet at all times.
- Perform a full discharge/recharge cycle every 3-6 months if the UPS is rarely used on battery power.
- Batteries are consumable items and will eventually require replacement. Contact qualified service personnel for battery replacement.
2. Чистење
- Disconnect the UPS from the AC power outlet and all connected devices before cleaning.
- Use a soft, dry cloth to wipe the exterior surfaces. Do not use liquid or aerosol cleaners.
- Осигурајте се дека отворите за вентилација се без прашина и остатоци.
3. Складирање
- If storing the UPS for an extended period, turn it off and disconnect it from all power sources.
- Да се чува на ладно и суво место.
- Recharge the UPS battery every 3 months to prevent battery degradation.
Решавање проблеми
Review the following common issues and solutions before contacting technical support.
| Проблем | Можна причина | Решение |
|---|---|---|
| UPS-от не се вклучува. | No AC input power. Battery deeply discharged. | Check AC power cord connection. Ensure wall outlet has power. Allow UPS to charge for 8 hours. |
| UPS beeps continuously in AC mode. | Overload condition. Internal fault. | Reduce connected load. Disconnect non-essential devices. If problem persists, contact support. |
| UPS-от често се префрла на режим на батерија. | Unstable utility power. Low battery capacity. | Check utility power quality. Allow battery to fully charge. Consider battery replacement if old. |
| Connected devices lose power during outage. | UPS overloaded. Battery depleted. | Ensure total load is within capacity. Allow UPS to recharge. |
Спецификации
| Карактеристика | Спецификација |
|---|---|
| Модел | UPSD2000VBK |
| Бренд | Недис |
| Капацитет | 2000 VA / 1200 W |
| Влез волуменtage | 120 волти (AC) |
| Излезни приклучоци | 4 (Schuko type) |
| Димензии (Д x Ш x В) | 14.5 x 40 x 20.5 cm |
| Тежина | 30 кг |
| Тип на батерија | Sealed Lead-Acid (internal, non-user replaceable) |
| Време на полнење | 8 часа до 90% капацитет (типично) |
| Работна температура | 0°C до 40°C |
| Влажност | 0-90% RH (некондензира) |
| Пристаниште за комуникација | USB |
| Заштита на мрежата | RJ45 (IN/OUT) |
Гаранција и поддршка
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Nedis website. Do not attempt to repair the unit yourself, as this may void your warranty and pose safety risks. Always contact qualified service personnel for assistance.