1. Вовед и производview
The Apera Instruments EC820 Benchtop Conductivity Meter is a high-precision instrument designed for accurate measurement of Conductivity (EC), Total Dissolved Solids (TDS), Salinity, Resistivity, and temperature. This meter is equipped with advanced features for reliable and stable readings across a wide range of applications.
This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your EC820 meter to ensure optimal performance and longevity.

Figure 1: Apera Instruments EC820 Benchtop Conductivity Meter Kit. The image shows the main meter unit, a flexible electrode arm and holder, and the conductivity electrode submerged in a beaker of liquid.
2. Безбедносни мерки на претпазливост
- Always handle the meter and electrodes with care to prevent damage.
- Do not immerse the main meter unit in water. The unit is IP54 water-resistant, but not submersible.
- Користете го само дадениот адаптер за напојување.
- Keep calibration solutions and samples away from children and pets. Follow safety data sheets (SDS) for handling specific chemicals.
- Ensure the meter is placed on a stable, level surface during operation.
- Исклучете го напојувањето пред чистење или вршење на одржување.
3. Содржина на пакетот
Проверете дали сите артикли наведени подолу се присутни во вашиот пакет:
- EC820 прецизен мерач на спроводливост на клупа
- 2401T-F Platinum Glass-body Conductivity Electrode
- Флексибилна рачка и држач за електрода
- USB кабел
- PC-Link софтверски флеш-драјв
- Адаптер за напојување (Влез: 120V AC 60Hz; Излез: 9V 300mA)
- Calibration Solutions:
- 84 µS/cm (1 vial)
- 1413 µS/cm (1 vial)
- 12.88 mS/cm (1 vial)

Figure 2: The 2401T-F Platinum Glass-body Conductivity Electrode, showing its connection cables.
4. Поставување
- Unpack the Meter: Внимателно отстранете ги сите компоненти од пакувањето.
- Assemble Electrode Arm: Attach the flexible electrode arm to the meter unit. Ensure it is securely fastened.
- Поврзете ја електродата: Plug the 2401T-F Conductivity Electrode into the designated "COND" port on the back of the meter. Ensure the connection is firm.

Figure 3: Rear panel of the EC820 meter, highlighting the "COND" and "TEMP" ports, along with RS232 and DC 9V power input.
- Поврзете напојување: Plug the power adapter into the "DC 9V" port on the back of the meter, then connect it to a standard 120V AC 60Hz power outlet.
- Почетно вклучување: Press the power button to turn on the meter. The LCD display should illuminate.
5. Упатства за работа
5.1. Калибрација
The EC820 meter features 1 to 4 points auto-calibration. Regular calibration ensures accurate measurements.
- Prepare Solutions: Use the provided 84 µS/cm, 1413 µS/cm, and 12.88 mS/cm calibration solutions. Ensure solutions are at room temperature.
- Електрода за плакнење: Rinse the conductivity electrode thoroughly with distilled or deionized water before and after each measurement or calibration. Gently blot dry with a lint-free tissue.
- Влезете во режим на калибрација: With the meter on, press the CAL button. The display will show "CAL" and prompt for the first calibration point.
- Калибрација на првата точка: Immerse the electrode into the 1413 µS/cm standard solution. Wait for the reading to stabilize (indicated by a stable icon on the display). The meter will automatically recognize the solution. Press ENTER да се потврди.
- Subsequent Points (Optional): For higher accuracy, proceed with 84 µS/cm and 12.88 mS/cm solutions following the same procedure. The meter will guide you through the process.
- Излез од калибрација: After completing desired calibration points, press the МЕАС button to return to measurement mode.
Забелешка: The meter has a self-diagnosis function to help identify and fix common calibration problems. Refer to the on-screen prompts.
5.2. Мерење
- Електрода за плакнење: Исплакнете ја електродата со дестилирана вода.
- Потопна електрода: Потопете ја електродата во sample solution, ensuring the sensor is fully submerged.
- Wait for Stability: Allow the reading to stabilize. The stable reading icon will appear on the LCD.
- Читање на записи: Read the Conductivity (EC), TDS, Salinity, or Resistivity value displayed on the large LCD. Temperature will also be displayed simultaneously.
- Промени единици: Притиснете го ЕДИНИЦА button to cycle through different measurement units (e.g., µS/cm, mS/cm, ppm, ppt).
- Складирање податоци: The meter supports GLP data management with 500 groups of data storage. Use the M+ / R-M buttons to store and recall data.
- Извоз на податоци: Connect the meter to a PC via the USB cable and use the provided PC-Link software (Windows-based system only) to export data.
6. Одржување
- Чистење на електроди:
- Regularly rinse the electrode with distilled or deionized water.
- For stubborn deposits, refer to the electrode's specific cleaning instructions. Generally, a mild detergent solution or a specific electrode cleaning solution can be used, followed by thorough rinsing.
- Do not scratch or damage the platinum black sensor.
- Складирање на електроди:
- Always store the conductivity electrode in its protective cap filled with a proper electrode storage solution (e.g., 3M KCl solution or Apera Instruments storage solution). Never store dry.
- Чистење на броилата: Wipe the main meter unit with a clean, damp крпа. Не користете абразивни средства за чистење или растворувачи.
- Ажурирања на софтверот: Check the Apera Instruments website periodically for any software updates for the PC-Link software.

Слика 4: Одблиску view of the platinum glass-body conductivity electrode tip, which requires careful handling and proper storage.
7 Смена на проблеми
| Проблем | Можна причина | Решение |
|---|---|---|
| Мерачот не се вклучува | Нема напојување; неисправен адаптер; лабава врска. | Check power adapter connection and outlet. Ensure adapter is functional. |
| Нестабилни читања | Dirty electrode; air bubbles on sensor; incorrect calibration; temperature fluctuations. | Clean electrode; gently tap electrode to remove bubbles; recalibrate meter; ensure sample temperature is stable. |
| Грешка при калибрација | Contaminated calibration solution; incorrect solution used; damaged electrode. | Use fresh calibration solutions; ensure correct solution for calibration point; inspect electrode for damage. |
| No data transfer to PC | Incorrect USB connection; software not installed or running; driver issues. | Verify USB cable connection; ensure PC-Link software is installed and open; check device manager for driver issues. |
8. Спецификации
| Параметар | Вредност |
|---|---|
| Број на модел | AI532 |
| Мерни параметри | Conductivity (EC), TDS, Salinity, Resistivity, Temperature |
| Опсег на спроводливост | 0 to 2,000 mS |
| Точност | ±0.5% FS |
| Точки за калибрација | 1 to 4 points auto-calibration (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) |
| Температурна компензација | Автоматска компензација на температурата (ATC) |
| Складирање на податоци | 500 групи (во согласност со GLP) |
| Поврзување | USB for PC data export |
| Тип на дисплеј | Голем LCD екран со позадинско осветлување |
| Напојување | 9V DC, 300mA (120V AC 60Hz adapter included) |
| Заштита од навлегување | IP54 Водоотпорен |
| Сертификати | CE, RoHS, ISO 9001:2015 |
| Димензии на пакетот | 10.63 x 9.88 x 6.61 инчи |
| Тежина | 6.5 фунти |
9. Гаранција и поддршка
Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of quality and reliability. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments webсајт.
For assistance with troubleshooting, calibration, or general inquiries, please contact Apera Instruments customer service. Contact details can typically be found on their official webлокацијата или во пакувањето на производот.
Онлајн ресурси: Apera Instruments Store on Amazon