1. Вовед
Thank you for choosing the Yuwell YX303 Fingertip Pulse Oximeter. This device is designed for non-invasive spot-check measurement of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate. It is suitable for use in hospitals, homecare, outdoor activities, and sports. Please read this manual carefully before use to ensure safe and effective operation.

Image 1.1: The Yuwell YX303 Fingertip Pulse Oximeter. This image shows the compact device, typically with a display screen and a finger insertion area.
2. Информации за безбедност
Важно: This device is intended for non-medical use and is not a substitute for professional medical advice or diagnosis. Consult your physician for any medical concerns.
- Не користете го оксиметарот во околина со МРИ или КТ.
- Do not use the oximeter in situations requiring continuous monitoring.
- Keep the device away from children. Small parts may be a choking hazard.
- Do not use the oximeter on the same arm as a blood pressure cuff or arterial catheter.
- Avoid placing the oximeter on fingers with nail polish, artificial nails, or excessive dirt, as this may affect accuracy.
- Ensure the finger is clean and dry before use.
3. Производот завршиview
3.1. Клучни карактеристики
- Low power consumption, simple to operate, light, and portable.
- Oxygen saturation (SpO2) and Pulse Rate (PR) display.
- Automatic power-off in 8 seconds when no finger is detected.
- Pulse strength indicator.
- Strong anti-interference capability.
3.2. Режими на прикажување
The device features an OLED display. It shows:
- Oxygen Saturation (SpO2) percentage.
- Pulse Rate (BPM).
- Pulse bar graph.
4. Поставување
4.1. Инсталација на батерија
- Отворете го капакот на преградата за батерии на задната страна на уредот.
- Insert two (2) AAA 1.5V alkaline batteries, ensuring correct polarity (+ and -).
- Добро затворете го капакот на преградата за батерии.
Уредот работи во рамките на еден волуменtagопсег од 2.6V до 3.6V.
5. Упатства за работа
- Ensure the oximeter has batteries installed.
- Отворете го clamp of the oximeter.
- Insert one finger into the rubber opening of the oximeter, ensuring the finger is placed correctly and comfortably.
- Ослободете го clamp. The oximeter will automatically turn on and begin measurement.
- Држете ја раката мирна за време на мерењето. Движењето може да влијае на точноста.
- Read the SpO2 and Pulse Rate values displayed on the OLED screen.
- After removing your finger, the device will automatically power off after approximately 8 seconds.
5.1. Measurement Accuracy Considerations
- Заситеност со кислород: Accuracy is ±2% for readings between 70% and 99%. For readings below 70%, accuracy is not defined.
- Стапка на пулсот: Accuracy is ±1% or ±1 BPM, whichever is greater.
- Weak Perfusion: The oximeter can accurately display oxygen saturation and pulse rate even with a pulse filling degree as low as 0.6%.
- Светлосна интерференција: Compared to measurements in a dark room, the deviation in oxygen saturation under natural light and illuminated conditions is less than ±1%.
6. Одржување
6.1. Чистење
- Исчистете ја површината на оксиметарот со мека крпа dampened with medical alcohol (75% ethanol) or isopropyl alcohol.
- Do not immerse the device in water or any cleaning solution.
- Пред повторна употреба, проверете дали уредот е целосно сув.
6.2. Складирање
- Store the oximeter in a cool, dry place, away from direct sunlight and extreme temperatures.
- Отстранете ги батериите ако уредот нема да се користи подолг период за да спречите истекување на батериите.
7 Смена на проблеми
| Проблем | Можна причина | Решение |
|---|---|---|
| Нема приказ по вклучувањето | Батериите се празни или неправилно инсталирани. | Заменете ги батериите или повторно инсталирајте ги со точен поларитет. |
| Неточни читања | Finger not inserted properly; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm finger. |
| "Finger Out" or similar error message | Finger not detected or improperly placed. | Ensure finger is fully inserted into the sensor. |
8. Спецификации
| Параметар | Вредност |
|---|---|
| Режим на прикажување | OLED дисплеј |
| Опсег на мерење на SpO2 | 70% ~ 100% |
| Точност на SpO2 | ±2% (70%~99%), undefined (<70%) |
| Опсег на мерење на пулсот | 25 ~ 250 BPM |
| Точност на пулсот | ±1% or ±1 BPM (whichever is greater) |
| Напојување | 2 x AAA 1.5V алкални батерии |
| Voltagе опсег | 2.6V ~ 3.6V |
| Потрошувачка на енергија | Помалку од 30 mA |
| Weak Perfusion Measurement | SpO2 and PR can be displayed when pulse filling degree is 0.6% |
| Автоматско исклучување | After 8 seconds of no finger use |
| Производител | ЈУВЕЛ |
| Број на модел | YX303 (Internal Item No: 31681163949) |
| Димензии на пакетот | 11.52 x 7.21 x 3.8 cm |
| Тежина | 300 g (вклучувајќи го и пакувањето) |
9. Гаранција и поддршка
For warranty information and customer support, please refer to the documentation provided with your purchase or contact your retailer. Keep your purchase receipt as proof of purchase.