TRUPER 13499

Упатство за употреба на пумпа за зголемување на притисокот Truper 13499 PRES-1/3T

Model: 13499 / PRES-1/3T

1. Вовед

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Truper 13499 PRES-1/3T 1/3 HP Pressure Booster Pump. Please read these instructions carefully before installation and use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Информации за безбедност

Секогаш почитувајте ги следните безбедносни мерки:

3. Компоненти на производот

The Truper 13499 PRES-1/3T Pressure Booster Pump includes the main pump unit, an integrated pressure switch, and power cord with an on/off switch. Refer to the image below for a visual representation of the pump and its key components.

Truper 13499 PRES-1/3T Pressure Booster Pump

Слика 1: Truper 13499 PRES-1/3T Pressure Booster Pump. This image shows the complete pump assembly, including the orange motor housing, the dark gray pump body, brass fittings for water inlet and outlet, and the integrated flow switch with an arrow indicating water flow direction. The power cord with an inline on/off switch is also visible.

Клучни компоненти:

4. Поставување и инсталација

Правилната инсталација е клучна за перформансите и долговечноста на пумпата.

  1. Локација:
    • Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures.
    • Осигурајте се дека пумпата е поставена на стабилна, рамна површина за да се минимизираат вибрациите.
    • Allow adequate space around the pump for ventilation and maintenance access.
  2. Водоводни врски:
    • Connect the pump to the water supply line using appropriate plumbing fittings. Ensure all connections are watertight.
    • Observe the flow direction indicated by the arrow on the flow switch (Figure 1). The pump must be installed in line with the water flow.
    • Use flexible connectors to reduce vibration transmission to the plumbing system.
    • Install shut-off valves on both the inlet and outlet sides of the pump for easier maintenance.
  3. Електрична врска:
    • Ensure the power outlet is properly grounded and matches the pump's electrical requirements (127 V - 60 Hz).
    • Plug the pump's power cord into the grounded outlet.
    • Do not use extension cords unless absolutely necessary, and ensure they are rated for the pump's power requirements.
  4. Грундирање на пумпата:
    • Before initial operation, ensure the pump is filled with water to prevent dry running. Open a faucet downstream to allow air to escape.
    • Once water flows steadily from the faucet, close it. The pump is now primed.

5. Упатства за работа

The Truper 13499 PRES-1/3T pump operates automatically based on water flow.

  1. Почетно стартување:
    • After installation and priming, ensure the inline switch on the power cord is in the "OFF" position.
    • Приклучете ја пумпата во соодветен штекер.
    • Switch the inline power switch to the "ON" position. The pump will remain off until water flow is detected.
  2. Автоматско работење:
    • When a water outlet (e.g., faucet, shower) is opened, the flow switch detects water movement.
    • The pump automatically starts, boosting water pressure.
    • When the water outlet is closed, the flow stops, and the pump automatically shuts off after a short delay.
  3. Циклус на должност:
    • The pump is designed for intermittent use: 50 minutes of work followed by 20 minutes of rest.
    • The daily maximum operating time is 6 hours. Adhering to this duty cycle will prolong the pump's lifespan.

6. Одржување

Редовното одржување обезбедува оптимални перформанси и го продолжува животниот век на вашата пумпа.

Warning: Always disconnect the pump from the power supply before performing any maintenance.

7 Смена на проблеми

This section addresses common issues you might encounter with your pressure booster pump.

ПроблемМожна причинаРешение
Пумпата не стартува.Нема напојување.
Inline switch is OFF.
No water flow detected.
Проверете го штекерот и прекинувачот.
Turn inline switch to ON.
Open a water outlet to initiate flow. Ensure pump is primed.
Пумпата работи постојано.Leak in plumbing system.
Flow switch malfunction.
Constant low water flow.
Check all connections for leaks and repair.
Контактирајте со квалификуван сервисен персонал.
Ensure all outlets are fully closed.
Insufficient pressure boost.Пумпата не е правилно наместена.
Inlet water pressure too low.
Obstruction in plumbing.
Повторно наполнете ја пумпата.
Ensure minimum input pressure of 0.72 PSI is met.
Inspect plumbing for blockages.
Пумпата е бучна или вибрира прекумерно.Воздух во системот.
Лабаво монтирање.
Абење на внатрешните компоненти.
Re-prime the pump to remove air.
Ensure pump is securely mounted on a stable surface.
Контактирајте со квалификуван сервисен персонал.

8. Технички спецификации

КарактеристикаСпецификација
Модел13499 / PRES-1/3T
Моќ1/3 HP (248 W)
Voltage - Frequency127 V - 60 Hz
Максимален проток15 gal/min (27 L/min) / 60 Liters Per Minute
Minimum Input Pressure0.72 PSI
Максимален притисок17 PSI
Циклус на должност50 min. work per 20 min. rest
Daily Maximum Operation6 часа
МатеријалАлуминиумска цasing
Тежина9 lb (4.3 Kg) / 10.36 pounds (shipping)
Dimensions (B x H x W)5 1/8" x 11 13/16" x 6 5/16" (13 x 30 x 16 cm) / 7.09 x 5.91 x 5.91 inches (product)
Water Outlets SupportedДо 3 истовремено
Тип на операцијаOn demand (Autostop switch)

9. Гаранција и поддршка

For warranty information or technical support, please refer to the documentation included with your purchase or contact Truper customer service. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official Truper webлокација или контактирајте ги нивните овластени сервисни центри.