1. Производот завршиview
The Leviton LB260-ES is a 60A, 2-Pole Plug-On Smart Ground Fault Protection of Equipment (GFPE) Branch Circuit Breaker. This hydraulic magnetic breaker is designed for 120/240 VAC systems with a 10KA Interrupt Rating. It is suitable for applications up to 60A when using copper wire or 50A when using aluminum wire.
This smart circuit breaker integrates with the My Leviton app, providing advanced features for home energy management and enhanced safety.
2. Информации за безбедност
ПРЕДУПРЕДУВАЊЕ: Installation and servicing of this circuit breaker must be performed by a qualified electrician in accordance with all national and local electrical codes. Failure to follow these instructions may result in serious injury or death.
- Always turn off the main power supply at the service panel before working on electrical circuits.
- Користете соодветна лична заштитна опрема (ЛЗО) за време на инсталацијата.
- Осигурајте се дека се исполнети соодветните спецификации за големината на жиците и вртежниот момент за сите врски.
- Овој производ содржи хемикалии за кои државата Калифорнија знае дека предизвикуваат рак и вродени дефекти или други репродуктивни штети (предупредување според Предлог 65).

Слика 1: Предна страна view of the Leviton LB260-ES circuit breaker.
3. Карактеристики на производот
- Паметна интеграција: Integrated with the My Leviton app, this breaker provides insightful data on home energy consumption, enhanced safety, and whole-home solutions in conjunction with other smart Leviton products.
- Лесна инсталација: Leviton's design allows the entire Load Center to be wired at rough-in without any circuit breakers present. The plug-on design simplifies installation.
- Hydraulic Magnetic Technology: Precision trip technology ensures consistent operation from -40°C to 85°C (-40°F to 185°F) without re-rating.
- Засилена безбедност: Features patented reset lockout technology, preventing the breaker from resetting if ground or arc fault protection is compromised.
4. Поставување и инсталација
The Leviton LB260-ES circuit breaker is designed for quick and secure installation within a compatible Leviton Load Center. The plug-on design eliminates the need for additional wiring to the breaker itself, as connections are made directly on the panel's bus bars.
Чекори за инсталација:
- Осигурајте се дека главното напојување до центарот за оптоварување е ИСКЛУЧЕНО.
- Prepare branch circuit wires (phase and neutral) by stripping insulation to the recommended length.
- Connect the branch phase and neutral wires directly to the designated terminals on the load center panel. This allows for neat wiring at rough-in without breakers in the way.
- Align the LB260-ES breaker with the appropriate slot in the load center.
- Firmly push the breaker onto the bus bar until it snaps securely into place. No additional wiring to the breaker is required.
- Verify all connections are secure and the breaker is properly seated.
- Once all breakers are installed and the panel cover is secured, restore main power.

Слика 2: Страна view illustrating the plug-on mechanism of the circuit breaker.
Видео за инсталација:
Video 1: This official Leviton video demonstrates the installation process and features of the Leviton Load Center and its plug-on circuit breakers, including wiring and smart capabilities.
5. Упатства за работа
The Leviton LB260-ES circuit breaker operates like a standard circuit breaker but includes smart functionalities accessible via the My Leviton app.
Рачно работење:
- ВКЛУЧЕН/ИСКЛУЧЕН прекинувач: To turn a circuit ON, push the switch to the 'ON' position. To turn it OFF, push the switch to the 'OFF' position.
- Прекинат прекинувач: If the breaker trips due to an overload or fault, the switch will move to a central, tripped position. To reset, first move the switch fully to the 'OFF' position, then to the 'ON' position. If the breaker immediately trips again, there is still a fault on the circuit that needs to be addressed.
Smart Features (via My Leviton App):
To utilize the smart features, download the My Leviton app and connect your Leviton Load Center and smart breakers according to the app's instructions.
- Мониторинг на енергија: View real-time energy consumption for individual circuits or the entire home. Track usage patterns over time to identify energy-saving opportunities.
- Далечински управувач: Remotely turn circuits ON or OFF from your smartphone or tablet.
- Anomaly Notifications: Receive alerts for electrical anomalies, such as unexpected power draws or circuit trips, directly to your device.
- Функционалност на само-тестирање: GFPE breakers feature self-test capabilities to ensure proper operation. The app may provide status updates on these tests.
6. Одржување
Leviton circuit breakers are designed for long-term reliability with minimal maintenance. However, periodic checks are recommended.
- Визуелна инспекција: Periodically inspect the circuit breaker and load center for any signs of damage, discoloration, or loose connections.
- GFPE Test: GFPE devices should be tested monthly. Press the 'TEST' button on the breaker. The breaker should trip immediately. Reset the breaker by moving the switch to 'OFF' then 'ON'. If the breaker does not trip or reset, it may be faulty and should be replaced by a qualified electrician.
- Чистење: Keep the load center area clean and free from dust and debris. Do not use liquids to clean inside the load center.
7 Смена на проблеми
If you encounter issues with your Leviton LB260-ES circuit breaker, refer to the following common troubleshooting steps:
| Проблем | Можна причина | Решение |
|---|---|---|
| Прекинувачот често патува | Преоптоварување, краток спој или грешка во заземјувањето. | Unplug appliances from the circuit. Reset the breaker. If it trips again, consult a qualified electrician to identify and fix the fault. |
| Прекинувачот не се ресетира | Persistent fault, or patented reset lockout engaged. | Ensure the switch is moved fully to 'OFF' before attempting to reset to 'ON'. If it still doesn't reset, a fault is present or the breaker is damaged. Consult a qualified electrician. |
| No energy data in My Leviton app | No internet connection, app not configured, or data hub issue. | Check your home's internet connection. Ensure the Leviton Load Center data hub is properly installed and connected. Verify app configuration and breaker pairing. |
| GFPE test button does not trip breaker | Faulty GFPE mechanism. | The breaker may be defective. It should be replaced immediately by a qualified electrician. |
For further assistance, refer to the My Leviton app's help section or contact Leviton customer support.
8. Спецификации
| Спецификација | Вредност |
|---|---|
| Бренд | Левитон |
| Број на модел | LB260-ES |
| Тековен рејтинг | 60 Amps |
| Број на Полјаци | 2 |
| Voltage | 120/240 волти наизменична струја |
| Тип на прекинувач на струјното коло | GFPE (Ground Fault Protection of Equipment) |
| Тип на монтирање | Монтирање за приклучок |
| Оценка за прекини | 10КА |
| Работна температура | -40°C до 85°C (-40°F до 185°F) |
| Тежина на ставката | 13.4 унци |
| Димензии на производот | 4 x 2.5 x 3.9 инчи |
9. Гаранција и поддршка
Информации за гаранцијата:
This Leviton LB260-ES circuit breaker is covered by a 10-годишна Ограничена гаранцијаЗа специфични услови и одредби, ве молиме погледнете ја гарантната документација вклучена во вашиот производ или посетете ја официјалната страница на Leviton. webсајт.
Поддршка за корисници:
For technical assistance, troubleshooting, or warranty claims, please contact Leviton Customer Support. You can find contact information on the official Leviton webстраницата или во апликацијата My Leviton.
Официјален Левитон Webсајт: www.leviton.com