Flamco 14670

Упатство за употреба на сад за експанзија за вода за пиење Flamco Airfix A од 35 литри

Модел: 14670

1. Вовед

1.1 Производ надview

The Flamco Airfix A 35 Liter Drinking Water Expansion Vessel (Model 14670) is a crucial component designed for use in drinking water heating systems. Its primary function is to absorb volume changes in the system caused by temperature fluctuations, thereby maintaining stable pressure and protecting system components. This vessel is constructed and tested according to DIN 4807 T5 standards, ensuring reliability and safety.

Key features include external and internal plastic coating for durability and hygiene, a flow distributor for efficient connection, and an external thread for secure wall mounting. It holds the DIN-DVGW approval mark: NW-0411AU2095 and is approved according to the EU Pressure Equipment Directive 97/23/EG.

Flamco Airfix A 35 Liter Expansion Vessel

Слика 1: Предна страна view of the Flamco Airfix A 35 Liter Drinking Water Expansion Vessel.

1.2 Безбедносни информации

ПРЕДУПРЕДУВАЊЕ: Improper installation, operation, or maintenance can lead to serious injury or property damage. Read this manual thoroughly before installation and operation.

2. Поставување и инсталација

2.1 Отпакување

Carefully remove the expansion vessel from its packaging. Inspect the vessel for any signs of damage during transit. Do not install a damaged vessel. Retain packaging materials for potential future transport or return.

2.2 Монтирање

The Flamco Airfix A vessel is designed for wall mounting.

  1. Select a suitable location near the drinking water heating system, ensuring adequate space for installation and future maintenance.
  2. Ensure the wall structure can safely support the weight of the vessel when full (approximately 9 kg empty + 35 kg water = 44 kg).
  3. Use appropriate wall anchors and screws (not supplied) to securely fasten the mounting bracket (if separate) or directly mount the vessel using its integrated hanging points.
  4. Mount the vessel in an upright position with the system connection facing downwards.

2.3 Системско поврзување

Connect the expansion vessel to the drinking water heating system using the external threaded connection.

Сечење view of Flamco Airfix A expansion vessel membrane

Слика 2: Внатрешно view showing the membrane and connection point of the expansion vessel.

2.4 Pre-charge Pressure Check

The vessel comes pre-charged from the factory. However, it is essential to verify and adjust the pre-charge pressure to match the system's static pressure at the point of installation.

  1. Before connecting the vessel to the system, check the pre-charge pressure using a suitable pressure gauge at the air valve (usually located at the top or side of the vessel).
  2. Adjust the pre-charge pressure to be slightly below (e.g., 0.2 bar) the static pressure of the drinking water system at the vessel's connection point.
  3. Use a bicycle pump or air compressor to add air, or depress the valve stem to release air, until the correct pressure is achieved.
  4. Once the pre-charge pressure is set, connect the vessel to the system and fill the system with water.

3. Принципи на работа

3.1 Функционалност

The Flamco Airfix A expansion vessel operates on the principle of a flexible membrane separating a water chamber from a pre-charged air chamber. As the water in the drinking water heating system heats up, it expands. This expanded water enters the vessel, compressing the air in the air chamber and causing the membrane to flex. This absorption of expanded water prevents excessive pressure buildup in the system. When the water cools down and contracts, the pre-charged air pushes the water back into the system, maintaining stable pressure.

3.2 Нормални работни услови

Under normal operating conditions, the vessel will silently absorb and release water as the system temperature fluctuates. There should be no noticeable noise or vibration from the vessel itself. The system pressure gauge should remain within the acceptable operating range for your drinking water heating system.

4. Насоки за одржување

Regular maintenance is essential to ensure the longevity and proper functioning of your Flamco Airfix A expansion vessel and the overall drinking water heating system.

4.1 Редовни инспекции

4.2 Pre-charge Pressure Verification

The pre-charge pressure of the expansion vessel should be checked and adjusted annually, or more frequently if system pressure fluctuations are observed.

  1. ВАЖНО: Before checking the pre-charge pressure, the system must be depressurized and the vessel isolated from the water supply.
  2. Close the isolation valve to the expansion vessel.
  3. Drain the water from the vessel by opening a nearby tap or drain valve until no more water flows out.
  4. Attach a pressure gauge to the air valve on the vessel.
  5. Read the pressure. If it is below the required static pressure of the system, add air using a pump until the correct pressure is reached. If it is too high, release air.
  6. Once the pressure is correct, close the drain valve, open the isolation valve to the vessel, and repressurize the system.

5. Водич за решавање проблеми

This section provides solutions to common issues that may arise with your expansion vessel. For problems not listed here, or if solutions do not resolve the issue, contact a qualified technician.

ПроблемМожна причинаРешение
System pressure fluctuates excessively.Incorrect pre-charge pressure, damaged membrane, or undersized vessel.Check and adjust pre-charge pressure (Section 4.2). If the issue persists, the membrane may be damaged, requiring vessel replacement. Consult a professional to verify vessel sizing.
Water leaks from the air valve.Damaged internal membrane.This indicates a failure of the internal membrane. The expansion vessel needs to be replaced.
Low system pressure despite adequate water supply.Loss of pre-charge pressure in the vessel.Check and adjust pre-charge pressure (Section 4.2).
Vessel feels heavy and full of water when tapped.Loss of pre-charge pressure, allowing water to fill the air chamber.Check and adjust pre-charge pressure (Section 4.2). If water cannot be drained from the air valve, the membrane is likely damaged, and the vessel requires replacement.

6. Технички спецификации

БрендФламко
МоделAirfix A
Број на модел14670
Капацитет35 литри
Димензии (Д x Ш x В)1 x 1 x 39.4 cm (Note: These dimensions seem unusually small for a 35L vessel, likely packaging or partial dimensions. Refer to manufacturer's full technical sheet for precise product dimensions.)
Тежина (празна)9 кг
Maximum Membrane Temperature70 °C
ОдобрувањаDIN 4807 T5, DIN-DVGW: NW-0411AU2095, EU Pressure Equipment Directive 97/23/EG
Тип на врскаНадворешна нишка
МонтирањеМонтирање на ѕид

7. Гаранција и корисничка поддршка

7.1 Информации за гаранцијата

Specific warranty details for the Flamco Airfix A 35 Liter Expansion Vessel are not provided in this document. Please refer to the official Flamco website or contact your point of purchase for comprehensive warranty terms and conditions. Keep your proof of purchase for warranty claims.

7.2 Информации за контакт

For technical assistance, spare parts, or further inquiries, please contact Flamco customer support or your local distributor. Contact details can typically be found on the official Flamco webсајт (www.flamco.com).

Поврзани документи - 14670

Предview Сад за експанзија Flamco Airfix A/D: Упатство за инсталација и работа
Сеопфатен водич за инсталирање и ракување со експанзиони садови Flamco Airfix A и Airfix D, кој опфаќа општи информации, примена, чекори за инсталација, безбедносни мерки на претпазливост, процедури за прва употреба, одржување и деинсталација. Вклучува технички спецификации.
Предview Упатства за инсталација и работа на експанзионен сад Flamco Contraflex
Сеопфатен водич за инсталирање, ракување и одржување на експанзиони садови Flamco Contraflex. Опфаќа безбедносни процедури, пуштање во работа и деинсталација за модели од 2 до 1000 литри.
Предview Насловна на монтирање и опис на Flamcomat G4 и Flamcomat стартер G4
Podrobný návod na montáž, prevádzku a údržbu expanzných automatov Flamcomat G4 a Flamcomat Starter G4 od spoločnosti Flamco. Obsahuje bezpečnostné pokyny, technické špecifikácie a riešenie problémov.
Предview Flamcomat MP G4 Прирачник за инсталација и работа
Сеопфатни упатства за инсталација и работа за автоматот за проширување Flamco Flamcomat MP G4. Опфаќаат безбедност, опис на производот, склопување, пуштање во работа, одржување и технички податоци.
Предview Тампон садови Flamco Flextherm PS-H(+): Водич за инсталација и работа
This guide provides essential technical data, safety instructions, installation procedures, and maintenance guidelines for Flamco Flextherm PS-H(+) buffer and intermediate vessels, designed to optimize heat pump performance and heating system efficiency.
Предview Вентил за ослободување на притисок Prescor - Водич за инсталација, безбедност и одржување
Сеопфатен водич за вентили за ослободување на притисок Prescor од Flamco, кој опфаќа примена, инсталација, безбедносни мерки на претпазливост, одржување и отстранување за системи за греење и ладење.