Circutor M22348.

DHC-96 mVdc Digital Voltmeter Shunt User Manual

Model: M22348. | Brand: Circutor

1. Вовед

The Circutor DHC-96 mVdc Digital Voltmeter Shunt (Model M22348.) is a sophisticated digital instrument panel designed for precise monitoring, regulation, and control of electrical variants and process signals. This device is capable of displaying measured electrical values or proportional values of process signals, making it suitable for a wide range of industrial and climate solar installations.

Главните карактеристики вклучуваат:

  • Висока точност во мерењето.
  • Programmable measurement input.
  • Integrated relay output for control and alarm functions.
  • Universal power supply compatibility (80-270 Vca/cc and 16-36 VCC).
  • Frontal IP 54 protection for enhanced durability.
  • Galvanic insulation between external circuits.
  • Self-configurable decimal point.
  • Designed for panel installation (96 x 49 mm).
Circutor DHC-96 mVdc Digital Voltmeter Shunt with red digital display showing '0.000 A' and control buttons below.

Слика 1: Предна страна view of the Circutor DHC-96 mVdc Digital Voltmeter Shunt, showing its digital display and control buttons.

2. Поставување и инсталација

Proper installation is crucial for the optimal performance and longevity of your DHC-96 device. Ensure all power sources are disconnected before proceeding with installation.

2.1 Монтирање на панел

  • Prepare a panel cutout with dimensions of 96 x 49 mm.
  • Insert the DHC-96 unit into the cutout from the front.
  • Secure the unit using the provided mounting clips or brackets from the rear of the panel. Ensure a snug fit to maintain the IP 54 frontal protection rating.

2.2 Поврзување со напојување

The DHC-96 supports a universal power supply. Connect the power source to the designated terminals on the rear of the unit.

  • For AC/DC power, connect to 80-270 Vca/cc terminals.
  • For DC power, connect to 16-36 VCC terminals.
  • Ensure correct polarity for DC connections.

2.3 Measurement Input Connection

Connect the signal source to the programmable measurement input terminals. Refer to the wiring diagram provided with your specific model for detailed connection points.

  • За волtage measurements, connect the voltagе извор.
  • For current measurements, connect through a shunt or current transformer as appropriate for your application.
  • Ensure galvanic insulation between external circuits is maintained.

2.4 Излезна врска со реле

The DHC-96 features two output relays for control and alarm functions. Connect these relays to your external control systems or alarm indicators as required.

  • Identify the relay output terminals.
  • Wire the relays according to your application's control logic.
  • Configure alarm delays and interlocking settings via the device's menu.

3. Упатства за работа

Once installed and powered, the DHC-96 is ready for operation. The front panel features a digital display and control buttons for configuration and monitoring.

3.1 Прикажи надview

The digital display shows the measured electrical variant (e.g., voltage, current, frequency) or the proportional value of a process signal. The unit automatically adjusts the display based on the configured measurement type.

  • DC Systems: Capable of measuring voltage, current, frequency, and other industrial process variables.
  • Модели за наизменична струја: Perform measurements in True Effective Value (TRMS).
  • Децимална точка: The decimal point is self-configurable to suit your measurement precision requirements.

3.2 Функции на копчињата

The front panel buttons allow for navigation through menus, parameter configuration, and display adjustments. Specific button functions may vary slightly depending on the firmware version.

  • Стрелки лево/десно (< / >): Typically used for navigating through menu options or adjusting values.
  • Стрелки нагоре/надолу ( / ): Се користи за зголемувањеasing/намалувањеasing values or selecting options.
  • Мени/копче Enter: Used to access the main menu, confirm selections, or save settings.
  • Escape/Back Button: Used to exit a menu or cancel an operation.

3.3 Configuration and Programming

The DHC-96 allows for programming various parameters to suit specific application needs. This includes setting the measurement input type, configuring alarm thresholds, and defining relay behaviors.

  • Access the configuration menu by pressing the Menu/Enter button.
  • Навигирајте низ опциите на менито користејќи ги копчињата со стрелки.
  • Select the desired parameter to modify and adjust its value.
  • Save changes before exiting the menu.
  • Refer to the detailed programming guide (if available separately) for advanced configurations.

4. Одржување

The DHC-96 is designed for reliable operation with minimal maintenance. Regular inspection and cleaning will help ensure its continued performance.

  • Чистење: Периодично чистете го предниот панел со мека, дamp крпа. Не користете абразивни средства за чистење или растворувачи, бидејќи тие може да го оштетат екранот илиasing.
  • Инспекција: Regularly inspect the wiring connections for any signs of wear, corrosion, or looseness. Ensure the unit is securely mounted in its panel cutout.
  • Животна средина: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage. The IP 54 frontal protection helps against dust and splashing water, but the unit is not designed for immersion.
  • Нема делови што се сервисираат од страна на корисникот: The DHC-96 contains no user-serviceable parts. Do not attempt to open the casing, as this will void the warranty and may expose you to electrical hazards.

5 Смена на проблеми

If you encounter issues with your DHC-96, refer to the following common troubleshooting steps. For problems not listed here, contact Circutor technical support.

  • Без дисплеј/напојување:
    • Check the power supply connections to ensure they are secure and correctly wired.
    • Проверете дали изворот на енергија има јачина на звукtage is within the specified range (80-270 Vca/cc or 16-36 VCC).
    • Check for any tripped circuit breakers or blown fuses in the power circuit.
  • Неточни читања:
    • Ensure the measurement input is correctly connected and the signal source is active.
    • Verify that the device's measurement input type is correctly configured in the settings to match your application (e.g., voltage, current, process signal).
    • Check for any external interference or noise affecting the signal.
    • Confirm the decimal point setting is appropriate for the expected values.
  • Релето не се активира:
    • Check the relay output wiring for proper connection to the external control system.
    • Verify the alarm thresholds and relay logic are correctly configured in the device's settings.
    • Ensure the measured value has exceeded or fallen below the set alarm threshold.
    • Check for any configured alarm delays or interlocking conditions that might prevent immediate activation.

6. Спецификации

АтрибутВредност
ПроизводителЦиркутор
Број на делМ22348.
Број на модел на ставкаМ22348.
Димензии на производот3.01 x 1.93 x 3.78 инчи
Тежина на ставката7 унци
БојаЦрното
СтилЦир
Извор на енергијаЕлектрични
Количина на пакет на ставка1
Потребни се батерии?бр
ASINB08WL8FMDB
Датум прв на располагање15 август 2023 година

7. Гаранција и поддршка

For detailed warranty information, please refer to the warranty card included with your product or visit the official Circutor webлокација. Условите за гаранција може да се разликуваат во зависност од регионот и производот.

For technical support, service, or inquiries regarding your DHC-96 mVdc Digital Voltmeter Shunt, please contact Circutor customer service or your authorized dealer. Provide your product model number (M22348.) and serial number (if applicable) when seeking support.

You can find more information and contact details on the official Circutor webсајт: www.circutor.com

Поврзани документи - М22348.

Предview Прирачник за станица за полнење електрични возила Circutor URBAN и URBAN WB
Упатство за користење и конфигурација за станиците за полнење електрични возила Circutor URBAN и URBAN WB, кое опфаќа инсталација, работа и технички спецификации.
Предview Водич за инсталација на конвертор Circutor line-TCPRS1 RS-485/RS-232 во TCP/IP
Водич за инсталација за линијата Circutor-TCPRS1, портал за конвертирање на физички средини од RS-485 или RS-232 во Ethernet и/или Wi-Fi. Карактеристики Web Поврзување со сервер и Android апликација.
Предview Инсталација и техничко упатство за анализатор на моќност CIRCUTOR CVM-E3-MINI-ITF-WiEth
Сеопфатно упатство за инсталација и технички спецификации за анализаторот на моќност CIRCUTOR CVM-E3-MINI-ITF-WiEth. Дознајте повеќе за неговите карактеристики, дијаграми за поврзување, мерења на електрични параметри и клучни оперативни функции за различни типови мрежи.
Предview Прирачник за инструкции за Circutor TCPRS1+ RS-485 to TCP/IP конвертор
Сеопфатен водич за конверторот Circutor TCPRS1+ RS-485 во TCP/IP, кој опфаќа безбедност, инсталација, работа, комуникации (Wi-Fi, Ethernet), технички спецификации и одржување.
Предview Circutor Bridge LR RS-485 - Упатство за употреба на LoRa™ конвертор
Сеопфатно упатство за Circutor Bridge LR, конвертор од RS-485 во LoRa™. Опфаќа инсталација, работа, технички карактеристики и конфигурација.
Предview Упатство за употреба на анализаторот на моќност од серијата Circutor CVM-C5
Упатство за анализатори на моќност од серијата Circutor CVM-C5, вклучувајќи ги моделите CVM-C5-ITF-485, CVM-C5-MC-485 и CVM-C5-mV-485. Обезбедува детални информации за инсталацијата, работата, програмирањето и техничките спецификации.