VAXCEL T0697

VAXCEL T0697 Bronze Motion Sensor Outdoor Security Flood Light User Manual

Модел: T0697

Вовед

Thank you for choosing the VAXCEL T0697 Bronze Motion Sensor Outdoor Security Flood Light. This manual provides detailed instructions for the safe installation, operation, and maintenance of your new security light. Please read all instructions carefully before installation and retain this manual for future reference.

VAXCEL Bronze Motion Sensor Outdoor Security Flood Light installed on a house

Image: The VAXCEL Bronze Motion Sensor Outdoor Security Flood Light mounted on the exterior of a house, illuminating the area.

Информации за безбедност

Што има во кутијата

Проверете дали сите компоненти се присутни пред да започнете со инсталацијата:

Note: Light bulbs (2 x 150 watt PAR 38 medium base E26 screw-in bulbs) are not included. LED compatible.

Поставување и инсталација

This VAXCEL security light is designed for hardwired installation and can be mounted to a wall or eave. Ensure the mounting surface is structurally sound and capable of supporting the fixture's weight.

Опции за монтирање

The fixture offers flexible mounting options, allowing for installation on either a wall or an eave. The light heads and motion sensor are adjustable to direct light where needed most.

Diagram showing wall mount and eave mount options for the flood light, with arrows indicating rotating light heads and sensor joint.

Image: A diagram illustrating the flexibility of the VAXCEL flood light, showing how it can be mounted on a wall or an eave, with arrows indicating the rotatable light heads and sensor joint for optimal positioning.

Инструкции за ожичување

  1. Исклучете го напојувањето на прекинувачот или кутијата со осигурувачи.
  2. Attach the mounting bracket to the junction box using the provided hardware.
  3. Connect the fixture's wires to the household wiring: black to black (live), white to white (neutral), and green/bare copper to green/bare copper (ground). Secure connections with wire nuts.
  4. Внимателно заглавете ги сите жици во разводна кутија.
  5. Mount the fixture to the mounting bracket, ensuring a tight seal against the mounting surface to prevent water intrusion.
  6. Install two PAR38 E26 base bulbs (not included) into the sockets.
  7. Вратете го напојувањето на прекинувачот.

Димензии на производот

Technical drawing of the VAXCEL flood light with dimensions: A: 8 inches, B: 11-3/4 inches, C: 8-3/4 inches.

Image: A technical drawing providing the precise measurements of the VAXCEL flood light fixture, indicating its length, width, and height for installation planning.

Упатства за работа

Your VAXCEL security flood light features advanced motion sensing and dusk-to-dawn capabilities, offering multiple modes for customized security and energy efficiency.

Diagram showing three light activation modes: Motion Sensor, Dusk to Dawn, and Switch Controlled.

Image: A visual representation of the three primary operational modes of the VAXCEL flood light: motion sensor activation, automatic dusk-to-dawn operation, and manual switch control.

Функција на сензор за движење

Diagram illustrating the 240-degree motion detection angle and 10-85 ft range, showing coverage around corners, flat walls, and inside corners.

Image: A graphic demonstrating the wide 240-degree detection angle and adjustable range (10-85 feet) of the motion sensor, highlighting its effectiveness in various outdoor settings including around corners and along walls.

Dusk-to-Dawn Photocell

The integrated photocell automatically turns the fixture on when it gets dark and off when it becomes light, providing continuous security and saving energy during daylight hours.

Dual-Level Brightness & Modes

Diagram showing customizable settings for the flood light, including motion shut-off delay, motion sensitivity, early evening timer, modes of operation, and dual-level brightness.

Image: A detailed graphic outlining the fully customizable settings of the VAXCEL flood light, including options for motion shut-off delay, sensitivity, early evening timer, various operating modes, and the dual-level brightness feature.

Одржување

Image of the VAXCEL flood light in rainy conditions, highlighting its outdoor durability and weather-resistant plastic material.

Image: The VAXCEL flood light shown enduring rain and snow, emphasizing its robust outdoor durability and weather-resistant construction.

Решавање проблеми

ПроблемМожна причинаРешение
Светлото не се вклучува.No power; faulty bulb; sensor malfunction.Check circuit breaker. Replace bulbs. Ensure sensor is clean and unobstructed.
Светлината останува постојано вклучена.Sensor in test mode; continuous motion detected; wiring error.Check sensor mode. Remove obstructions. Verify wiring connections.
Светлината трепка или трепка.Loose wiring; incompatible bulb; power fluctuations.Check all wiring connections. Use recommended bulbs. Consult an electrician if power issues persist.
Сензорот за движење не детектира.Sensor obstructed; incorrect sensitivity setting; improper angle.Clear obstructions. Adjust sensitivity. Reposition sensor for optimal coverage.

Спецификации

КарактеристикаДетал
БрендВАКСЕЛ
Име на моделотТ0697
БојаБронза
МатеријалПластика
Димензии на производот8.75"Д x 11.75"Ш x 8"В
Внатрешна/надворешна употребаНа отворено
Извор на енергијаХарджирано
Тип на инсталацијаWall Mounted (also Eave Mount)
Посебни карактеристикиAdjustable Heads, Dusk to Dawn Sensor, Motion Sensor
Опсег на сензор за движење240 Degree, 85 Ft.
Основа за сијалицаE26 Средно
Ватtagд (максимум)2 x 150 watts (bulbs not included)
Voltage120 волти
Ниво на отпорност на водаВодоотпорен
СертификацијаНаведени ETL

Гаранција

This VAXCEL product comes with a limited warranty. Please refer to the warranty card included in your packaging for specific terms and conditions, or visit the VAXCEL webсајт за повеќе информации.

Видео за производот

Погледнете го ова видео за повеќеview of VAXCEL lighting products, showcasing various styles and applications.

Video: An informational video titled "About Vaxcel Lighting" providing a general overview of VAXCEL's lighting solutions.

Поддршка за корисници

For further assistance, technical support, or warranty claims, please contact VAXCEL customer service. Contact information can typically be found on the VAXCEL webна локацијата или на пакувањето на производот.

Поврзани документи - Т0697

Предview Vaxcel T0804/T0805 Motion Sensor Outdoor Wall Sconce: Assembly and Installation Guide
Comprehensive assembly and installation instructions for the Vaxcel T0804 and T0805 motion sensor outdoor wall sconces. Learn how to install, operate, and troubleshoot your fixture.
Предview Надворешна ѕидна ламба со сензор за движење Vaxcel T0804/T0805: Водич за склопување и инсталација
Сеопфатни упатства за склопување и инсталација на ѕидната ламба со сензор за движење на отворено Vaxcel T0804 и T0805. Опфаќа карактеристики, режими на работа, прилагодување, решавање проблеми, резервни делови и гаранција.
Предview Vaxcel T0694/T0695 Motion Activated Light Installation and Mounting Instructions
This guide provides detailed instructions for installing and operating the Vaxcel T0694/T0695 motion activated outdoor light fixture. It covers important safety information, features, mounting options, sensor and light head adjustments, various operating modes, troubleshooting tips, and warranty details.
Предview Упатства за склопување и инсталација на Vaxcel T0739
Овој документ дава упатства за склопување и инсталација на светилката Vaxcel T0739. Вклучува список на хардверски пакет, упатства за склопување чекор-по-чекор, опционални упатства за исклучување на фотоќелијата и информации за гаранцијата.
Предview Упатства за склопување и инсталација на Vaxcel T0571
Detailed assembly and installation instructions for the Vaxcel T0571 outdoor light fixture, including hardware lists, wiring diagrams, and warranty information.
Предview Vaxcel T0633/T0634 Outdoor Wall Light Assembly and Installation Instructions
Comprehensive guide for assembling and installing Vaxcel T0633 and T0634 outdoor wall lights. Includes hardware details, step-by-step installation, optional photocell disconnection, spare parts, and dimensions.