GOYOJO UV-759

GOYOJO UV-759 UV Visible Double Beam Spectrophotometer Instruction Manual

Model: UV-759 | Brand: GOYOJO

1. Вовед

The GOYOJO UV-759 UV Visible Double Beam Spectrophotometer is an advanced instrument designed for precise laboratory testing and scientific research. This new generation intelligent instrument features a dual beam optical system, ensuring high stability and a strong signal-to-noise ratio. It offers high resolution and low stray light, making it suitable for daily analysis and various scientific applications.

This manual provides essential information for the safe and efficient operation of your spectrophotometer, including setup, operational procedures, maintenance, and troubleshooting.

GOYOJO UV-759 Spectrophotometer with 'scanning ultraviolet visible spectrophotometer' text and 'Product introduction' section

Слика 1.1: Готовоview of the GOYOJO UV-759 Spectrophotometer highlighting its scanning capabilities and product introduction.

2. Информации за безбедност

Секогаш почитувајте ги следниве безбедносни мерки за да спречите повреда и оштетување на инструментот:

  • Ensure the instrument is connected to a grounded power outlet with the correct voltage (220 V ± 10% 50 Hz ± 1 Hz).
  • Do not operate the instrument in environments with excessive humidity, dust, or corrosive gases.
  • Avoid direct exposure to the UV light source.
  • Do not open the instrument casing освен ако не е наложено од квалификуван сервисен персонал.
  • Handle cuvettes and samples with care, especially when dealing with hazardous chemicals.

3. Содржина на пакетот

По распакувањето, проверете дали сите компоненти се присутни и неоштетени:

  • GOYOJO UV-759 Spectrophotometer Unit
  • Кабел за напојување
  • USB Communication Cable (for RS232 interface)
  • Cuvettes (quantity may vary)
  • Упатство за употреба
  • Софтверско ЦД (доколку е применливо)

4. Поставување

4.1 Отпакување и поставување

Carefully remove the spectrophotometer from its packaging. Place the instrument on a stable, level surface away from direct sunlight, vibrations, and strong electromagnetic fields. Ensure adequate ventilation around the unit.

Предна страна view of the GOYOJO UV-759 Spectrophotometer

Слика 4.1: напред view of the GOYOJO UV-759 Spectrophotometer, showing the main unit and control panel.

4.2 Поврзување за напојување

Connect the provided power cable to the power inlet on the rear of the instrument and then to a suitable grounded electrical outlet. Ensure the power switch is in the OFF position before connecting.

Заден дел view of the GOYOJO UV-759 Spectrophotometer showing power inlet and communication ports

Image 4.2: Rear panel of the spectrophotometer, illustrating the power input and RS232 communication port.

4.3 Communication Setup (Optional)

If connecting to a computer for data acquisition or control, use the provided USB cable to connect the RS232 communication port on the instrument to your computer. Install any necessary drivers or software as per the instructions provided with the software package.

5. Упатства за работа

5.1 Powering On and Initial Warm-up

  1. Flip the power switch on the rear of the instrument to the ON position.
  2. The instrument will perform a self-test. Allow approximately 15-30 minutes for the lamps to warm up and stabilize for accurate measurements.
  3. The display will show the main menu or a ready state once warm-up is complete.
Close-up of the GOYOJO UV-759 Spectrophotometer control panel with LCD display and keypad

Слика 5.1: Детално view of the control panel, including the LCD screen and function keys.

5.2 Basic Measurement Procedure

  1. Изберете режим: From the main menu, select the desired measurement mode (e.g., Absorbance, Transmittance, Concentration, or Quantitative).
  2. Set Wavelength: Use the keypad to enter the desired wavelength for your measurement. Press ENTER.
  3. Prepare Blank: Fill a clean cuvette with your blank solution (e.g., solvent). Insert it into the sampпреградата.
  4. Zero/Calibrate: Press the "ZERO" or "CAL" button to set the baseline or zero the instrument with the blank.
  5. Подгответе го Сampле: Remove the blank and insert a cuvette containing your sampЛе решение во сampпреградата.
  6. Мерење: Press the "START" or "MEASURE" button to initiate the measurement. The result will be displayed on the screen.
  7. Повторете: За повеќе сamples, repeat steps 5 and 6.
GOYOJO UV-759 Spectrophotometer with the sample compartment open, showing the cuvette holder

Image 5.2: The sample compartment opened, revealing the cuvette holder for sample insertion.

5.3 Напредни функции

Refer to the detailed software manual (if applicable) for instructions on advanced functions such as spectral scanning, kinetics, and multi-wavelength analysis. These functions typically require connection to a computer and specialized software.

6. Одржување

6.1 Чистење

  • Надворешност: Избришете ги надворешните површини со мека, гamp крпа. Не користете абразивни средства за чистење или растворувачи.
  • Sample Compartment: Чувајте го сample compartment clean and dry. Use a lint-free cloth to remove any spills.
  • Cuvettes: Always use clean cuvettes. Rinse them thoroughly with appropriate solvent and dry them before use.

6.2 лamp Замена

The UV and Visible lamps have a finite lifespan. When lamp performance degrades (e.g., unstable readings, low energy), they may need replacement. This procedure should ideally be performed by qualified service personnel or by following specific instructions in a service manual, as it involves sensitive optical components.

6.3 Складирање

When not in use for extended periods, power off the instrument, disconnect it from the power supply, and cover it with a dust cover to protect it from dust and environmental contaminants.

7 Смена на проблеми

ПроблемМожна причинаРешение
Уредот не се вклучуваPower cable disconnected; Power switch off; No power from outletCheck power cable connection; Ensure power switch is ON; Verify power outlet functionality
Нестабилни читањаInstrument not warmed up; Dirty cuvettes; Air bubbles in sample; Lamp при крајот на живототAllow adequate warm-up time; Clean cuvettes thoroughly; Remove air bubbles; Consider lamp замена
No light detected / Error messageLamp failure; Sample compartment lid open; Optical path blockedПроверете лamp status; Ensure sample compartment lid is closed; Verify no obstructions in optical path
Communication error with PCIncorrect cable; Driver not installed; Software settings incorrectUse correct USB/RS232 cable; Install necessary drivers; Configure software communication settings

8. Спецификации

The following table outlines the key technical specifications for the GOYOJO UV-759 UV Visible Double Beam Spectrophotometer:

Table of product parameters for the GOYOJO UV-759 Spectrophotometer

Image 8.1: Key technical specifications of the spectrophotometer.

ПараметарВредност
Име на производUV Visible Double Beam Spectrophotometer
МоделUV-759 (MAKIT-82530)
Опсег на бранова должина190-1100 nm
Точност на бранова должина± 0.3 nm
Wavelength Repeatability0.1 nm
Spectral Bandwidth1.8 nm
Transmittance Accuracy± 0.3% T
Фотометриски опсег-3 ~ 3a, 0-200% T, 0 ~ 9999c
Baseline Straightness± 0.001 A/h
Залутана светлина0.05% T@220nm, 360nm
Стабилност± 0.001 A/h @ 500nm
RS232 комуникацијаUSB интерфејс
Напојување220 V ± 10% 50 Hz ± 1 Hz, 70 W
Тежина18 кг

9. Гаранција и поддршка

9.1 Информации за гаранцијата

GOYOJO products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact GOYOJO customer service. Keep your purchase receipt as proof of purchase.

9.2 Поддршка за корисници

If you encounter any issues not covered in this manual or require technical assistance, please contact GOYOJO customer support. Provide your product model (UV-759) and serial number (if applicable) when contacting support for faster service.

For contact information, please visit the official GOYOJO webстраницата или погледнете го пакувањето на вашиот производ.

Поврзани документи - УВ-759

Предview Гојоџо GYJ-R Енергетски дисперзивен рендгенски спектрометар - Технички спецификации
Detailed technical specifications and features of the Goyojo GYJ-R Energy Dispersive X-ray Spectrometer (EDXRF), including hardware, software, and RoHS analysis capabilities. This document outlines the product's performance indicators, operational conditions, and after-sales service.
Предview GOYOJO Professional Weather Station: Features, Setup, and Operation Guide
Comprehensive guide to the GOYOJO Professional Weather Station, covering its features, wireless sensor connectivity, app integration with Tuya Smart, setup instructions, time/unit settings, alarm functions, readings, weather forecasting, and mounting.
Предview Прирачник со упатства за лабораториска вага GOYOJO
Упатство за употреба на електронски лабораториски ваги GOYOJO, со детали за спецификациите, подготовката, калибрацијата, работата и пораките за грешки.
Предview GOYOJO SRG-1 Portable Roughness Tester User Manual
User manual for the GOYOJO SRG-1 Portable Roughness Tester, detailing its features, operation, technical specifications, maintenance, and data definitions.
Предview Упатство за употреба на монокулар за термичко снимање од серијата GOYOJO GR
Сеопфатно упатство за употреба на монокулари за термичко снимање GOYOJO GR225, GR235, GR325, GR335 и GR335L. Опфаќа работа, безбедност, одржување и карактеристики на производот за апликации за термичко снимање на отворено.
Предview Упатство за употреба на монокулар за термичко снимање GOYOJO
Сеопфатно упатство за корисникот за термички монокулар GOYOJO, со детални упатства за безбедност, производ погореview, спецификации за перформанси, упатства за работа, одржување и информации за уредот.