Tecmojo 18U Wall Mount Server Cabinet

Tecmojo 18U Wall Mount Server Cabinet & 8 Outlet Rack Mount Power Strip Instruction Manual

Model: 18U Wall Mount Server Cabinet

Brand: Tecmojo

1. Вовед

This manual provides detailed instructions for the assembly, installation, operation, and maintenance of your Tecmojo 18U Wall Mount Server Cabinet and the accompanying 8 Outlet Rack Mount Power Strip. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.

2. Информации за безбедност

  • Always ensure the cabinet is securely mounted to a structurally sound wall capable of supporting the cabinet's weight plus the weight of all installed equipment.
  • Do not exceed the maximum weight capacity of 110 lbs (50 kg) for the cabinet.
  • Ensure all electrical connections are made by qualified personnel and comply with local electrical codes.
  • Do not block ventilation openings on the cabinet. Proper airflow is essential to prevent overheating.
  • Use appropriate personal protective equipment (PPE) during installation, such as gloves and eye protection.
  • Држете ги децата и домашните миленици подалеку од местото на инсталација.

3. Содржина на пакетот

Проверете дали сите компоненти наведени подолу се присутни пред да започнете со склопување:

  • Долниот панел
  • Top Cover (with fans)
  • Предна стаклена врата
  • Front Frame (2 pieces)
  • Rack Rails (4 pieces)
  • Side Panels (2 pieces)
  • Задна корица
  • Fixed Brackets (4 pieces)
  • Конзолна полица
  • L Загради
  • Тркалца (4 парчиња)
  • 8 Outlet Rack Mount Power Strip
  • Assorted Screws, Nuts, and Keys

4. Спецификации

4.1. 18U Wall Mount Server Cabinet

  • Решетки единици: 18U
  • Материјал: Heavy Duty Cold Rolled Steel
  • Тежински капацитет: До 110 фунти (50 кг)
  • Димензии (Д x Д x В): 21.7" x 17.7" x 34.8" (550мм x 450мм x 883мм)
  • Тип на монтирање: Wall Mount (also supports floor standing with casters)
  • Влезна врата: Reversible Locking Tempered Glass Door
  • Странични панели: Lockable and Removable
  • Ладење: One built-in top fan (expandable with additional fan slot), flow-through ventilation
  • Управување со кабли: Removable top and bottom panels for easy cable routing, knock-off holes
  • Усогласеност: EIA/ECA-310-E Compliant

4.2. 8 Outlet Rack Mount Power Strip

  • Број на продажни места: 8 NEMA5-15R
  • Влезен конектор: 1 НЕМА 5-15П
  • Тековен рејтинг: 15A (12A UL Certified)
  • Оперативен волtage: 125V AC
  • Заштита од пренапони: Да
  • LED индикатори: Ground (Green), Surge (Red)
  • Кабел за напојување: Интегриран кабел за напојување од 6 стапки
  • Монтирање: 1U Rack-mountable, fits standard 19" server racks
  • Префрли: Illuminated ON/OFF switch with protective cover
  • Тежина на производот: 4 фунти
  • Домување: Ладно валан челик
  • Сертификација: UL сертифициран

5. Склопување и монтажа

5.1. Server Cabinet Assembly (Floor Standing)

Follow these steps to assemble your server cabinet for floor-standing use. Refer to the provided assembly videos for visual guidance.

  1. Attach Front Frames to Bottom Panel: Secure the two front frame pieces to the vented side of the bottom panel using the provided screws.
  2. Secure Back Cover to Bottom Panel: Attach the back cover to the bottom panel using the appropriate screws.
  3. Place Top Cover: Position the top cover onto the assembled frame and fasten it with the provided screws. Ensure all accessories are correctly spliced and secured.
  4. Инсталирајте Rack Rails: Install the four rack rails uniformly according to your desired equipment depth. Use the provided screws to fix them in place.
  5. Соберете странични панели: Attach the left and right side panels in sequence.
  6. Install Front Glass Door: Align the joints, move the bolt, and install the front glass door. Ensure it opens and closes smoothly.
  7. Инсталирајте тркалца: Invert the rack, fix the bottom panel, and install the four casters using M6 bolts and nuts.

Video: Tecmojo Standard Wall Mount Cabinet Installation Guide. This video demonstrates the step-by-step assembly of the server cabinet, including attaching frames, panels, and installing casters.

Video: Tecmojo Elite 15/18U Wall Mount Server Cabinet Assembly. This video provides a visual guide for assembling the 15/18U cabinet, showing the installation of various components.

5.2. Server Cabinet Wall Mounted Installation

Ако претпочитате монтирање на ѕид, следете ги овие чекори:

  1. Remove Casters: If casters were installed, remove them.
  2. Fix Wall Mount Bracket: Secure the wall mount bracket to your desired wall location using appropriate screws and anchors (not included, ensure they are suitable for your wall type and the cabinet's weight). A drilling template is included for easy installation.
  3. Hang and Secure Cabinet: Carefully hang the assembled cabinet onto the fixed wall mount bracket. Secure the cabinet to the bracket with additional screws.
Wall mounting hole drilling template and cabinet features

Image: Wall mounting hole drilling template and key features like removable side panels and knock-off holes for cable management.

5.3. Power Strip Installation

The 8 Outlet Rack Mount Power Strip is designed for seamless integration into standard 19" server racks.

  1. Идентификувајте ја локацијата за монтирање: Choose a 1U space within your server cabinet for the power strip.
  2. Secure Power Strip: Align the mounting brackets of the power strip with the rack rails and secure it using appropriate rack screws (typically 10-32 or 12-24, depending on your rack rails).
  3. Поврзете напојување: Plug the integrated 6ft power cord into a suitable wall outlet.
8-Outlet Rack-Mount Power Strip with Surge Protection features

Слика: Детална view of the 8-Outlet Rack-Mount Power Strip, highlighting its 8 NEMA5-15 outlets and mounting brackets for standard racks.

6. Операција

6.1. Server Cabinet Fans

The server cabinet includes one built-in top fan for ventilation. This fan helps to prevent overheating of your network equipment by increasing airflow. Additional fans can be installed in the available slots if needed.

6.2. Лента за напојување

  • Прекинувач: The power strip features an illuminated ON/OFF switch with a protective cover. Flip the switch to the 'ON' position to supply power to the outlets.
  • LED индикатори: The green LED indicates a proper ground connection, while the red LED indicates active surge protection.

6.3. Thermostat (if applicable)

Some models of the Tecmojo Wall Mount Server Cabinet may include a thermostat for fan control. If your model includes this feature, you can set your preferred temperature. The fans will activate automatically when the internal temperature exceeds the set threshold, ensuring optimal cooling.

Video: Wall Mount Server Cabinet with Thermostat. This video demonstrates how to set the thermostat to your preferred temperature for automatic fan control.

7. Одржување

  • Чистење: Regularly clean the exterior of the cabinet with a soft, dry cloth. For the glass door, use a glass cleaner. Ensure no liquids enter the cabinet.
  • Инспекција на вентилаторот: Periodically check the top fans for dust accumulation. Clean the fan blades gently with a soft brush or compressed air to maintain efficient cooling.
  • Управување со кабли: Ensure cables are neatly organized and not obstructing airflow or door closure.
  • Механизам за заклучување: Lubricate the door and side panel lock mechanisms periodically to ensure smooth operation.

8 Смена на проблеми

  • No Power to Power Strip:
    • Check if the power strip's ON/OFF switch is in the 'ON' position.
    • Verify the power cord is securely plugged into a working wall outlet.
    • Проверете го прекинувачот за ѕидниот штекер.
  • Fans Not Operating:
    • Ensure the cabinet is receiving power.
    • If your model has a thermostat, check its settings to ensure the temperature threshold has been met.
    • Inspect fan wiring for any loose connections.
  • Прегревање на опремата:
    • Ensure cabinet fans are operating correctly.
    • Check for any obstructions to airflow within the cabinet or at the ventilation openings.
    • Consider installing additional fans if the heat load is high.

9. Гаранција и поддршка

Tecmojo products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or contact Tecmojo customer support. Our customer service team is available to assist with any questions or issues you may encounter.

Контакт информации: Please refer to the product packaging or Tecmojo's official webстраница за најактуелните контакт информации за корисничка поддршка.

Поврзани документи - 18U Wall Mount Server Cabinet

Предview Упатство за употреба на ѕиден кабинет од серијата Tecmojo Elite
Упатство за употреба за ѕидниот кабинет со стаклена врата од серијата Tecmojo Elite. Вклучува спецификации, безбедносни предупредувања и упатства за склопување на куќишта за мрежни полици.
Предview Tecmojo Open Frame Rack за сервери и AV опрема - Упатство за употреба
Сеопфатно упатство за употреба на полиците со отворена рамка на Tecmojo за сервери и AV опрема. Вклучува спецификации, безбедносни упатства и упатства за склопување за моделите 11120121, 11120122 и 11120123.
Предview Упатство за употреба на мрежен кабинет Tecmojo - Инсталација и спецификации
Сеопфатно упатство за мрежни кабинети Tecmojo, вклучувајќи чекори за склопување, листи на хардвер, спецификации и безбедносни упатства. Опфаќа модели од 12130101 до 12130306.
Предview Упатство за употреба на полица за ѕидна монтажа на нишалка Tecmojo
Сеопфатно упатство за ѕидната решетка за нишалка Tecmojo, со детални спецификации, хардвер, додатоци и чекор-по-чекор инсталација за безбедно монтирање на опремата.
Предview Упатство за употреба на челичен серверски решетка со квадратни дупки од Tecmojo со 2 столба
Упатство со упатства за челичниот регал за сервери со 2 столба и квадратни дупки од Tecmojo, со детални спецификации, делови и чекори за склопување за различни U капацитети.
Предview Упатство за употреба на ѕиден AV решетка од Tecmojo
Детално упатство за употреба на ѕидни AV полици Tecmojo, кое опфаќа безбедност, спецификации и чекор-по-чекор склопување за моделите 11120101, 11120102 и 11120103. Вклучува списоци со хардвер и делови.