1. Вовед
This manual provides detailed instructions for the installation, operation, and maintenance of your ECOELER Motion Sensor Dimmer Light Switch, Model YM2601-WH. This in-wall electronic dimmer features PIR infrared motion activation, offering both Occupancy and Vacancy modes for convenient, hands-free lighting control. It is designed for single-pole applications and is compatible with dimmable LED/CFL and incandescent/halogen bulbs.

Figure 1: ECOELER Motion Sensor Dimmer Light Switch in a living room setting.
2. Карактеристики на производот
The ECOELER Motion Sensor Dimmer Light Switch offers a range of features designed for enhanced convenience and energy efficiency:
- Контрола без раце: Utilizes motion and ambient light sensors to automatically activate lights upon presence detection, eliminating the need for manual switching in dark environments.
- Customization Settings: Allows selection between Occupancy (Auto ON, Auto OFF) and Vacancy (Manual ON, Auto OFF) sensor modes. Adjustable time delay options include 15 seconds (Test), 1 minute, 5 minutes, 15 minutes, and 30 minutes.
- Digital Dimmer Switch: Features MCU-based digital control for smooth, flicker-free dimming across a wide range of compatible LEDs, with customizable dimming curves. Ideal for various indoor spaces such as bathrooms, closets, garages, and basements.
- Универзална компатибилност: Supports dimmable LED/CFL bulbs up to 150W and Incandescent & Halogen bulbs up to 300W. Designed for single-pole control circuits only (not suitable for 3-way circuits). A neutral wire is required for installation.
- Лесна инсталација: Designed to fit standard junction boxes, occupying only one device space. Suitable for study rooms, hallways, and restrooms.
- Trusted & Reliable: Constructed with a tough thermoplastic housing resistant to impacts and scratches, ensuring long-term durability. Includes a 1-year warranty for peace of mind.

Слика 2: Детално view of the product's adjustable features.

Figure 3: Programmable features for time delay, sensitivity, and light sensor.
3. Поставување и инсталација
Proper installation is crucial for the safe and effective operation of your dimmer switch. If you are unfamiliar with electrical wiring, it is recommended to consult a qualified electrician.
3.1 Безбедносни мерки на претпазливост
- ПРЕДУПРЕДУВАЊЕ: Power must be turned OFF at the circuit breaker before proceeding with installation. Failure to do so may result in serious injury or death.
- Verify that the circuit is de-energized using a voltagтестер пред да допрете какви било жици.
- This device is for single-pole applications only. Do NOT use in 3-way circuits.
- A neutral wire is REQUIRED for this switch to function.
3.2 Водич за поврзување
Follow the wiring diagram below to connect your dimmer switch:

Figure 4: Wiring diagram showing connections for Load, Hot, Neutral, and Ground wires.
- Black Wire (Hot): Connect to the incoming 120V AC line wire.
- Red Wire (Load): Connect to the wire leading to your light fixture.
- Бела жица (неутрална): Connect to the neutral wire from your electrical box.
- Green Wire (Ground): Connect to the bare copper or green ground wire from your electrical box.
3.3 Чекори за инсталација
- Исклучете го напојувањето на прекинувачот.
- Отстранете ја постојната ѕидна плоча и прекинувач.
- Identify the Line (Hot), Load, Neutral, and Ground wires. Use a voltage tester to confirm the hot wire is de-energized.
- Connect the ECOELER dimmer switch wires to the corresponding house wires using wire nuts. Ensure all connections are secure.
- Carefully push all wires back into the electrical box.
- Mount the dimmer switch into the electrical box using the provided screws.
- Прицврстете ја ѕидната плоча.
- Вратете го напојувањето на прекинувачот.
3.4 Видео за инсталација
Video 1: Installation guide for the RAYZEEK RZ020-5A-S Motion Sensor Switch, demonstrating wiring and mounting.
Video 2: How to Install 3 IN 1 Motion Sensor Switch, providing visual steps for the installation process.
4. Работни режими
The ECOELER Motion Sensor Dimmer Light Switch offers flexible operating modes to suit your needs:
4.1 Occupancy Mode (Auto ON, Auto OFF)
In Occupancy Mode, the light automatically turns ON when motion is detected and automatically turns OFF after a set time delay when no motion is detected. This mode is ideal for high-traffic areas where lights are frequently needed.

Figure 5: Occupancy mode in action, providing hands-free lighting.
4.2 Vacancy Mode (Manual ON, Auto OFF)
In Vacancy Mode, the light must be manually turned ON, but it will automatically turn OFF after a set time delay when no motion is detected. This mode is suitable for areas where you prefer manual control over when the light comes on, but still want the energy-saving benefit of automatic shut-off.

Figure 6: Vacancy mode, requiring manual activation but offering automatic turn-off.
4.3 Temporary Manual Override
You can temporarily override the sensor's automatic function by pressing the main button. The light will turn ON or OFF temporarily. After the set time delay expires, the switch will return to its last programmed working mode, and all settings will remain unchanged.
4.4 Manual ON/OFF Mode
This mode allows the sensor switch to function as a regular ON/OFF switch. The motion sensor will still detect motion, indicated by a red flash, but it will not trigger the light to turn ON. To activate this mode, short press the small button. To exit, short press the big button.
Video 3: How to use 3 IN 1 Motion Sensor Switch, detailing factory settings, temporary override, and manual ON/OFF mode.
5. Customization and Settings
The ECOELER Motion Sensor Dimmer Light Switch allows for easy customization of its settings without removing the wall plate.
5.1 Adjusting Time Delay
To customize the time delay, press and hold the big button. The red indicator will flash 1-6 times, corresponding to different time settings:
- 1 flash: 15 seconds (Test mode)
- 2 flashes: 1 minute
- 3 flashes: 3 minutes
- 4 flashes: 5 minutes
- 5 flashes: 15 minutes
- 6 flashes: 30 minutes
5.2 Customizing Working Mode
To change the working mode (Vacancy, Occupancy, or Occupancy without light sensor), press and hold the small button. The red indicator will flash 1-3 times:
- 1 flash: Vacancy mode
- 2 flashes: Occupancy mode
- 3 flashes: Occupancy without light sensor mode (ignores ambient light levels, always responds to motion).
5.3 Adjusting Light Sensor and Sensitivity
To adjust the light sensor value or sensitivity, press and hold both the big and small buttons simultaneously. The red and green indicators will flash 1-6 times:
- 1 flash: Low sensitivity
- 2 flashes: High sensitivity
- 3 flashes: Light sensor 15 LUX
- 4 flashes: Light sensor 25 LUX
- 5 flashes: Light sensor 35 LUX
- 6 flashes: Restore to factory settings
Video 4: RAYZEEK | RZ020 Motion Sensor Switch User Guide, demonstrating how to adjust time delay, working mode, and sensitivity.
6. Одржување
To ensure optimal performance and longevity of your ECOELER Motion Sensor Dimmer Light Switch, follow these maintenance guidelines:
- Чистење: Gently wipe the surface of the switch and wall plate with a soft, damp крпа. Избегнувајте употреба на абразивни средства за чистење, растворувачи или груби хемикалии, бидејќи тие можат да ја оштетат завршната обработка или внатрешните компоненти.
- Инспекција: Periodically check the switch for any signs of physical damage, loose connections, or unusual operation. If any issues are observed, turn off the power at the circuit breaker and consult a qualified electrician.
- Животна средина: Ensure the switch is installed in a dry indoor location, away from direct moisture or extreme temperatures, to prevent damage and ensure proper function.
7 Смена на проблеми
If you experience issues with your ECOELER Motion Sensor Dimmer Light Switch, refer to the following troubleshooting tips:
| Проблем | Можна причина | Решение |
|---|---|---|
| Light does not turn ON with motion. | Incorrect mode setting (e.g., Vacancy mode selected). Insufficient ambient light (if light sensor is active). Motion sensor sensitivity too low. Нема струја до прекинувачот. | Verify the switch is in Occupancy mode. Adjust ambient light sensor setting or test in darker conditions. Increase motion sensor sensitivity (refer to Section 5.3). Проверете го прекинувачот и жиците за поврзување. |
| Light does not turn OFF automatically. | Откриено е континуирано движење. Временското одложување е поставено предолго. Switch stuck in Manual ON mode. | Осигурајте се дека нема континуирано движење во опсегот на сензорот. Adjust time delay to a shorter duration (refer to Section 5.1). Exit Manual ON mode by pressing the big button. |
| Lights flicker or do not dim smoothly. | Некомпатибилен тип на сијалица. Сијалица ватtage exceeds switch capacity. Poor wiring connection. | Ensure dimmable LED/CFL or incandescent/halogen bulbs are used. Verify total bulb wattage is within switch limits (150W LED/CFL, 300W Incandescent/Halogen). Проверете ги сите жици за затегнатост. |
| Прекинувачот не реагира. | Нема струја до прекинувачот. Внатрешна грешка. | Check circuit breaker. If power is present and switch is still unresponsive, contact customer support. |
8. Спецификации
Key technical specifications for the ECOELER Motion Sensor Dimmer Light Switch (Model YM2601-WH):
| Спецификација | Вредност |
|---|---|
| Број на модел | YM2601-WH |
| Влез волуменtage | 120 волти (AC) |
| Тековен рејтинг | 10 Amps |
| Макс Ватtage (LED/CFL со можност за затемнување) | 150 W |
| Макс Ватtage (Инкандесцентно/Халогенско) | 300 W |
| Тип на прекинувач | Single-Pole, Push Button |
| Тип на сензор | PIR Infrared Motion, Ambient Light |
| Работни режими | Occupancy (Auto ON/OFF), Vacancy (Manual ON/Auto OFF) |
| Прилагодливо временско доцнење | 15s, 1min, 5min, 15min, 30min |
| Материјал | Copper, Metal, Polycarbonate |
| Димензии на производот | 6.86 x 4.2 x 11.48 cm |
| Тежина на ставката | 132 гр |
| Сертификати | ETL, FCC |
9. Гаранција и поддршка
ECOELER products are built with safety and reliability in mind. Your Motion Sensor Dimmer Light Switch comes with a 1 година гаранција од датумот на купување.
For technical assistance, troubleshooting, or warranty claims, please contact ECOELER customer support at SUPPORTS@ECOELER.COM. Please have your model number (YM2601-WH) and purchase information ready when contacting support.