Hantek DSO2D50

Hantek DSO2D50 Digital Storage Oscilloscope User Manual

Model: DSO2D50

1. Вовед

The Hantek DSO2D50 is a high-performance digital storage oscilloscope designed for precise signal analysis and measurement. It features a 500MHz bandwidth, 2GSa/s real-time sampling rate, and an 80K memory depth. This instrument also integrates a 25MHz arbitrary waveform generator, making it a versatile tool for various electronic testing and development applications.

This manual provides essential information for the safe and effective operation of your DSO2D50 oscilloscope. Please read it thoroughly before use and retain it for future reference.

Hantek DSO2D50 Digital Storage Oscilloscope front view

Слика 1.1: Предна страна view of the Hantek DSO2D50 Digital Storage Oscilloscope.

Клучни карактеристики:

2. Информации за безбедност

ПРЕДУПРЕДУВАЊЕ:

Rear panel of Hantek DSO2D50 with warning label

Figure 2.1: Rear panel showing power input and safety warning.

Опасен волtage inside, do not remove the cover unless by specified personnel.

3. Содржина на пакетот

Потврдете дека вашиот пакет ги содржи следниве ставки:

If any items are missing or damaged, please contact your dealer or Hantek customer support immediately.

4. Производот завршиview

4.1 Контроли и конектори на предниот панел

The front panel of the DSO2D50 features the display, control buttons, knobs, and input connectors for channels and the arbitrary waveform generator output.

Детално view of Hantek DSO2D50 control panel

Слика 4.1: Детално view of the control panel and input connectors.

Key areas include:

4.2 Конектори за задниот панел

Задниот панел вклучува влез за напојување и вентилација.

5. Поставување

5.1 Поврзување за напојување

  1. Осигурајте се дека прекинувачот за напојување на осцилоскопот е во положба OFF (Исклучено).
  2. Поврзете го испорачаниот кабел за напојување со влезот за наизменична струја на задниот панел на осцилоскопот.
  3. Вклучете го другиот крај од кабелот за напојување во заземјен штекер за наизменична струја.

5.2 Поврзување и компензација на сондата

  1. Connect a passive probe to one of the CH1 or CH2 BNC input connectors.
  2. Set the probe attenuation switch (if applicable) to 10X.
  3. Connect the probe ground clip to the oscilloscope's ground terminal (usually a dedicated terminal or the ground ring of the BNC connector).
  4. Connect the probe tip to the probe compensation output (usually a square wave test signal output on the front panel).
  5. Power on the oscilloscope.
  6. Притиснете го AUTO SET button. The oscilloscope will automatically adjust settings to display the compensation signal.
  7. Adjust the compensation screw on the probe until a flat-top square wave is displayed on the screen. This ensures accurate measurements.

6. Упатства за работа

6.1 Основен приказ на бранови форми

  1. Power on the oscilloscope.
  2. Connect a compensated probe to CH1.
  3. Connect the probe tip to the signal source you wish to measure.
  4. Притиснете го AUTO SET button. The oscilloscope will automatically adjust the vertical, horizontal, and trigger settings to display a stable waveform.
  5. Користете го VOLTS/DIV knob to adjust the vertical scale (ampлитуда).
  6. Користете го SEC/DIV knob to adjust the horizontal scale (time base).
  7. Користете го ПОЗИЦИЈА копчиња за поместување на брановата форма вертикално или хоризонтално.

6.2 1MΩ/50Ω Impedance Switching

The DSO2D50 supports switching between 1MΩ (high impedance) and 50Ω (low impedance) input impedance. This is crucial for adapting to different measurement scenarios and ensuring signal integrity, especially for high-frequency signals or when matching transmission lines.

Oscilloscope screen showing impedance switching menu

Figure 6.1: Menu for selecting input impedance.

To switch impedance:

  1. Притиснете го CH1 MENU or CH2 MENU button for the desired channel.
  2. Navigate through the menu options using the function buttons (F0-F6) until you find the "Impedance" setting.
  3. Изберете или 1MΩ or 50Ω as required for your measurement.
  4. Забелешка: When using 50Ω impedance, ensure your signal source is also 50Ω terminated to prevent reflections.

6.3 Measurement and Statistical Functions

The oscilloscope provides 32 automatic measurement functions and threshold measurement functions. These tools support statistical analysis, allowing you to display five measurement values: current value, average value, maximum value, minimum value, and standard deviation.

Oscilloscope screen displaying multiple automatic measurements

Слика 6.2: Прample of automatic measurement display.

To access measurement functions:

  1. Притиснете го МЕРКА копче.
  2. Use the function buttons to select the desired measurement type (e.g., Frequency, Period, Vpp, Vmax, Vmin, Rise Time, Fall Time).
  3. The selected measurements will appear on the screen.
  4. На view statistical values, navigate to the statistical menu within the MEASURE options.

6.4 Built-in Arbitrary Waveform Generator (AWG)

The DSO2D50 includes a 25MHz arbitrary waveform generator capable of outputting five standard waveforms: sine wave, square wave, triangle wave, exponential wave, noise, and DC. It also supports custom arbitrary waveform output.

Oscilloscope screen showing arbitrary waveform generator settings

Figure 6.3: Arbitrary Waveform Generator settings interface.

To use the AWG:

  1. Connect a BNC cable from the EXT TRIG/GEN OUT connector to the input of the device under test or an oscilloscope channel.
  2. Притиснете го WAVE GEN копче.
  3. Use the function buttons to select the desired waveform type (Sine, Square, Triangle, etc.).
  4. Прилагодете ги параметрите како што се фреквенцијата, Amplitude, and Offset using the corresponding menu options and knobs.
  5. Ensure the AWG output is enabled within the menu.

6.5 Triggering Modes

The oscilloscope offers 9 triggering modes to stabilize and capture specific events in your waveform. Common modes include Edge, Pulse, Video, Slope, and more advanced options for serial bus decoding.

To set up a trigger:

  1. Притиснете го TRIG MENU копче.
  2. Select the desired trigger type (e.g., Edge, Pulse).
  3. Adjust the trigger source (CH1, CH2, EXT), slope (rising/falling edge), and level using the НИВО НА АКТИВУВАЊЕ knob and menu options.
  4. The trigger level is indicated by a horizontal line on the display.

6.6 Складирање и повикување на податоци

The DSO2D50 allows you to save and recall various data types, including CSV files, images, reference waveforms, and waveform data, to a USB storage device.

To save data:

  1. Insert a USB flash drive into the USB Host port on the front panel.
  2. Притиснете го SAVE TO USB копче.
  3. Select the desired save type (e.g., Image, Waveform, CSV) and file format from the menu.
  4. Потврдете ја операцијата за зачувување.

6.7 Напредни функции

7. Одржување

7.1 Чистење

7.2 Складирање

7.3 Калибрација

The DSO2D50 is factory calibrated. For continued accuracy, periodic calibration by qualified service personnel is recommended, typically every 1-2 years depending on usage.

8 Смена на проблеми

Проблем Можна причина Решение
Нема приказ по вклучувањето. Power cord not connected, power switch off, or power supply issue. Check power cord connection. Ensure power switch is ON. Verify power outlet functionality.
Не е прикажан брановиот облик. Probe not connected, signal source off, vertical/horizontal scale incorrect, or trigger not set. Check probe connection. Ensure signal source is active. Press AUTO SET. Adjust VOLTS/DIV and SEC/DIV. Check trigger settings.
Unstable waveform. Incorrect trigger settings. Adjust trigger level. Change trigger type (e.g., from Auto to Normal). Check trigger source.
Мерењата се неточни. Probe compensation incorrect, probe attenuation setting mismatch, or incorrect impedance. Perform probe compensation. Ensure probe attenuation (1X/10X) matches oscilloscope setting. Verify input impedance (1MΩ/50Ω).
USB storage not recognized. Incompatible USB drive, drive not formatted correctly, or drive issue. Try a different USB drive. Ensure drive is formatted to FAT32.

9. Спецификации

The following table outlines the key specifications for the Hantek DSO2D50 Digital Storage Oscilloscope.

Параметар Спецификација
Модел DSO2D50
Канали 2 Analog Channels + 1 External Trigger Channel
Пропусен опсег 500 MHz
Sampling Стапка 2 GSa/s (Real-time)
Длабочина на меморија 80 Kpts
Произволен генератор на бранови форми 25 MHz (Sine, Square, Triangle, Exponential, Noise, DC)
Вертикална чувствителност 500 µV/div - 10 V/div
Влезна импеданса 1 MΩ ±2% || 15 pF ±5 pF; 50 Ω ±2%
Максимален влезен волуменtage 300 V CAT II (1MΩ)
Приказ 7-инчен TFT LCD
Режими на активирање Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, UART, LIN, CAN, SPI, IIC
Automatic Measurements 32 types, with statistical analysis
Интерфејс USB Host, USB Device
Напојување 100-240V AC, 50/60Hz
Потрошувачка на енергија < 50W
Димензии (Refer to package dimensions, typically 5.91 x 3.94 x 0.79 inches for package, actual unit size will be larger)
Тежина 12.1 фунти (тежина на ставката)

Забелешка: Specifications are subject to change without notice. For the most current specifications, please refer to the manufacturer's official webсајт.

9.1 Споредба на модели

The Hantek DSO2D50 is part of a series of oscilloscopes. The following table provides a comparison with other models in the series, highlighting key differences.

Table comparing Hantek oscilloscope models

Figure 9.1: Model comparison table for Hantek oscilloscopes.

This table helps to understand the DSO2D50's position within the product line, specifically noting its 500MHz bandwidth, 2GSa/s sampling rate, 80K storage depth, and integrated arbitrary function generator (AFG).

10. Гаранција и поддршка

10.1 Информации за гаранцијата

Hantek products are typically covered by a limited warranty against defects in materials and workmanship. The specific warranty period and terms may vary by region and product. Please refer to the warranty card included with your product or visit the official Hantek webсајт за детални информации за гаранцијата.

Зачувајте ја сметката како доказ за купување за гаранциски побарувања.

10.2 Поддршка за корисници

For technical assistance, troubleshooting, or service inquiries, please contact Hantek customer support:

When contacting support, please have your product model (DSO2D50) and serial number ready.