GENMAX GM12500iET

Упатство за користење на генераторот со три-горивни инвертори GENMAX GM12500iET

Model: GM12500iET

1. Информации за безбедност

Operating a generator requires adherence to strict safety guidelines to prevent injury or property damage. Always read and understand the entire manual before operating the GENMAX GM12500iET generator.

Carbon Monoxide (CO) Safety

This generator is equipped with a built-in CO sensor for enhanced safety. The CO sensor is designed to shut down the generator if harmful levels of carbon monoxide accumulate in the operating area. However, this feature is a supplement and does not replace safe operating practices.

  • Operate Outdoors Only: Always operate the generator outdoors in a well-ventilated area, far away from windows, doors, and vents to prevent carbon monoxide from entering enclosed spaces.
  • Exhaust Direction: Осигурајте се дека издувните гасови се насочени подалеку од луѓе и згради.
  • Аларми за CO: Install battery-operated carbon monoxide alarms in your home or RV and check them regularly.

Безбедност на горивото

  • Flammable Fuels: Gasoline, propane (LPG), and natural gas (NG) are highly flammable. Handle all fuels with extreme caution.
  • No Smoking: Do not smoke or allow open flames near the generator or fuel storage areas.
  • Полнење гориво: Always turn off the generator and allow it to cool before refueling with gasoline.
  • Складирање: Store fuels in approved containers in a well-ventilated area, away from ignition sources.

Електрична безбедност

  • Суви услови: Никогаш не го користете генераторот во влажни услови, дожд или снег. Држете ги рацете суви кога ракувате со електрични компоненти.
  • Заземјување: Осигурајте се дека генераторот е правилно заземјен според локалните електрични прописи.
  • Заштита од преоптоварување: Do not overload the generator. Utilize the circuit breakers to prevent damage.
  • Излези на GFCI: The generator features GFCI outlets for protection against electric shock.

2. Производот завршиview

The GENMAX GM12500iET is a powerful and versatile tri-fuel inverter generator designed for various applications, including home backup, RV use, and camping. It offers flexible fueling options, clean power output, and multiple starting methods.

GENMAX GM12500iET Tri-Fuel Inverter Generator with various fuel types

Image: The GENMAX GM12500iET Tri-Fuel Inverter Generator shown with gasoline, propane, and natural gas options, highlighting its versatile fuel technology.

Клучни карактеристики

  • Можност за три горива: Operates on Gasoline (12500 surge, 10500 running watts), Propane (LPG 11500 surge, 9500 running watts), and Natural Gas (NG 10000 surge, 8500 running watts).
  • Clean Inverter Power: Delivers less than 3% Total Harmonic Distortion (THD), making it safe for sensitive electronics.
  • High-Capacity Output: Features a 458cc OHV engine with multiple outlets including 120V/240V 50A (NEMA 14-50R), 120V 30A, 120V 20A, 12V DC, and dual USB ports.
  • Паметна дигитална контрола: Digital display shows wattagд, томtage, frequency, runtime, fuel level, and alerts.
  • 4-Way Start: Electric Start, Bluetooth App, 2-Wire Auto Start, and Recoil Backup.
  • Еко-режим: Automatically adjusts engine speed to load, reducing noise and extending runtime.
  • Преносен дизајн: Equipped with a robust frame, wheels, and a foldable handle for easy transport.
  • Безбедносни карактеристики: Includes a built-in CO sensor and comprehensive protection against overload, over/under voltage, краток спој и прегревање.
GENMAX GM12500iET generator in various scenarios like home backup, RV, camping, and job sites

Image: The GENMAX GM12500iET generator is depicted as suitable for multiple scenarios, including home backup, RV travel, camping, and powering tools at job sites.

3. Поставување

Before starting the generator, proper setup is crucial for safe and efficient operation.

3.1 Дебокс и проверка

  • Внимателно извадете го генераторот и сите додатоци од пакувањето.
  • Inspect the generator for any signs of shipping damage. If damage is found, contact customer support immediately.
  • Verify all included components are present as listed in the 'What Comes in the Box' section.
Contents of the GENMAX GM12500iET box including tools and accessories

Image: A visual representation of the items included in the GENMAX GM12500iET package, such as a spark plug wrench, screwdriver, remote control key, funnel, battery charger, NG quick connector, LPG hose, NG hose, and automatic start/stop cable.

3.2 Склоп на тркало и рачка

Attach the wheels and foldable handle using the provided hardware. This design facilitates easy transport of the generator.

Person pulling the GENMAX GM12500iET generator using its foldable handle and durable wheels

Image: A person easily transporting the GENMAX GM12500iET generator across a lawn, demonstrating its easy transport design with a foldable handle and durable wheels.

3.3 Додавање моторно масло

  • Пронајдете го капачето за полнење/мерката за масло.
  • Осигурајте се дека генераторот е на рамна површина.
  • Using the provided funnel, slowly add the recommended engine oil (refer to specifications for type and capacity) until it reaches the upper mark on the dipstick. Do not overfill.
  • Безбедно заменете го капачето за полнење масло.

3.4 Поврзување на батеријата

  • Пронајдете ја преградата за батерии.
  • Connect the positive (+) battery cable (red) to the positive (+) terminal and the negative (-) battery cable (black) to the negative (-) terminal. Ensure connections are secure.

3.5 Приклучок за гориво

The GM12500iET supports three fuel types: Gasoline, Propane (LPG), and Natural Gas (NG).

  • Бензин: Fill the fuel tank with fresh, unleaded gasoline. Do not use E85 or mixed fuels.
  • Пропан (ТНГ): Connect a standard propane tank to the dedicated LPG inlet using the provided LPG hose. Ensure all connections are tight to prevent leaks.
  • Природен гас (НГ): Connect to a natural gas supply line using the provided NG hose and quick connector. Ensure connections are secure and leak-free.

Важно: Only use one fuel type at a time. Select the desired fuel using the fuel selector switch on the control panel.

Video: A detailed instructional video (22:55) covering the setup and initial preparation of the GENMAX GM12500iET Tri-Fuel Inverter Generator.

4. Упатства за работа

Follow these steps to safely start and operate your GENMAX GM12500iET generator.

4.1 Контролната табла е завршенаview

Пред работа, запознајте се со компонентите на контролната табла.

Детално view of the GENMAX GM12500iET generator control panel with labeled components

Слика: Крупен план view of the generator's control panel, showing the digital display, main switch, fuel source switch, LPG/NG inlet, AC breakers, ground terminal, various AC outlets (50A, 30A, 20A), DC 12V outlet, USB ports, and the battery charging port.

4.2 Стартување на генераторот

The GM12500iET offers four starting methods:

  1. Електричен старт:
    • Осигурајте се дека генераторот е на рамна површина и дека сите врски се безбедни.
    • Select the desired fuel type using the fuel source switch.
    • Turn the main switch to the 'ON' position.
    • Press and hold the 'START/STOP' button until the engine starts.
  2. Bluetooth App Start:
    • Download the GENMAX app to your smartphone.
    • Pair your device with the generator via Bluetooth.
    • Follow the in-app instructions to start the generator remotely.
  3. 2-Wire Auto Start (for Home Backup):
    • Connect the provided 2-wire auto start cable to a compatible automatic transfer switch (ATS) or home backup system.
    • Ensure the 'AUTO GEN START SW' is in the 'ON' position.
    • The generator will automatically start when power is lost and shut down when utility power returns.
    GENMAX GM12500iET generator with auto start feature connected to an RV

    Image: The GENMAX GM12500iET generator is shown providing power to an RV, illustrating the convenience of its Auto Gen Start feature with a communication cable for automatic starting and stopping.

  4. Recoil Backup Start:
    • Ensure the main switch is 'ON' and fuel is selected.
    • Цврсто и непречено повлечете ја рачката на стартерот со отскок додека не се запали моторот.

4.3 Работа во еко-режим

Engage Eco-Mode by pressing the 'ECO' button on the control panel. In Eco-Mode, the engine speed automatically adjusts to the electrical load, which reduces fuel consumption and noise levels, especially during light load conditions. This feature extends runtime and is ideal for quiet environments.

GENMAX GM12500iET generator operating quietly outside a house

Image: The GENMAX GM12500iET generator operating outdoors, demonstrating its stable sine wave and low-noise technology, with a sound level indicator showing 62 dB at 7 meters.

4.4 Поврзување на електрични оптоварувања

  • Once the generator is running stably, plug in your electrical devices or connect to your transfer switch.
  • Do not exceed the generator's rated running wattage. Monitor the digital display for wattage излез.
  • Ensure all connected devices are in good working order and their power requirements are within the generator's capacity.

Video: An instructional video (4:28) demonstrating the operational procedures and features of the GENMAX GM12500iET generator.

5. Одржување

Regular maintenance ensures the longevity and reliable performance of your GENMAX GM12500iET generator.

5.1 Моторно масло

  • Проверете го нивото на маслото: Before each use, check the engine oil level and add if necessary.
  • Промена на масло: Change the engine oil after the first 20 hours of operation, then every 100 hours or annually, whichever comes first. Refer to the specifications for recommended oil type.

5.2 Филтер за воздух

  • Инспекција: Inspect the air filter element every 50 hours or monthly.
  • Чистење/Замена: Clean or replace the air filter element as needed, especially in dusty conditions. A dirty air filter can reduce engine performance and increase fuel consumption.

5.3 Свеќичка

  • Инспекција: Проверувајте ја свеќичката на секои 100 часа или годишно.
  • Чистење/Замена: Clean or replace the spark plug if it is fouled or worn. Ensure the gap is set correctly according to the engine specifications.

5.4 Систем за гориво

  • Филтер за гориво: Inspect and clean or replace the fuel filter as recommended in the full manual.
  • Складирање на гориво: For gasoline, use a fuel stabilizer if storing the generator for extended periods. Drain the carburetor if storing for more than 30 days without stabilizer.

5.5 Општо чистење и складирање

  • Чувајте го генераторот чист и без остатоци.
  • Чувајте го генераторот на суво, добро проветрено место, подалеку од директна сончева светлина и екстремни температури.
  • If storing for an extended period, perform all necessary maintenance, including draining fuel (for gasoline) or disconnecting propane/natural gas lines.

6 Смена на проблеми

This section provides solutions to common operational issues. For more complex problems, contact GENMAX technical support.

ПроблемМожна причинаРешение
Моторот нема да започне
  • No fuel or incorrect fuel type selected
  • Ниско ниво на моторно масло
  • Батеријата е испразнета (за електрично стартување)
  • Свеќичката е извалкана или оштетена
  • Main switch OFF
  • Add fuel and select correct type
  • Fill engine oil to proper level
  • Наполнете или заменете ја батеријата
  • Исчистете или заменете ја свеќичката
  • Turn main switch ON
Low power output / Engine stalls under load
  • Overloaded generator
  • Нечист филтер за воздух
  • Застоено или контаминирано гориво
  • Eco-Mode engaged with heavy load
  • Намалете го електричното оптоварување
  • Исчистете или заменете го филтерот за воздух
  • Испразнете го и наполнете го со свежо гориво
  • Disengage Eco-Mode for full power
Generator runs but no power output
  • Прекинувачот се сопна
  • Лабави електрични приклучоци
  • Ресетирајте ги прекинувачите
  • Проверете ги и обезбедете ги сите врски
CO sensor shutdown
  • Откриени се високи нивоа на јаглерод моноксид
  • Move generator to a well-ventilated outdoor area
  • Allow area to clear before restarting

Video: A brief instructional video (3:36) that may cover common troubleshooting steps or specific features of the generator.

7. Спецификации

Detailed technical specifications for the GENMAX GM12500iET Tri-Fuel Inverter Generator.

КарактеристикаСпецификација
Име на моделотGM12500iET
БрендGENMAX
Тип на мотор4-тактен, OHV
Зафатнина на моторот458 кубни сантиметри
Тип на горивоTri Fuel (Gasoline, Propane, Natural Gas)
Gasoline Starting Wattage12500 вати
Gasoline Running Wattage10500 вати
Propane (LPG) Starting Wattage11500 вати
Propane (LPG) Running Wattage9500 вати
Natural Gas (NG) Starting Wattage10000 вати
Natural Gas (NG) Running Wattage8500 вати
Волумен на резервоарот6.1 галони
Вкупно хармонично изобличување (THD)≤3%
Noise Level (25% load)Дури 62 dB(A)
Димензии на производот (Д x Ш x В)30.9" x 22.63" x 29.33"
Тежина на ставката251.92 фунти
Посебни карактеристикиCO Sensor, Bluetooth, 2-Wire Auto Start, Eco-Mode
Вклучени компонентиSpark Plug Socket Wrench, Wrench, Remote Control Key, Funnel, Battery Charger, NG Quick Connector, LPG Hose, NG Hose, Automatic Start/Stop Cable

8. Гаранција и поддршка

GENMAX is committed to providing reliable products and customer satisfaction.

8.1 Информации за гаранцијата

The GENMAX GM12500iET Tri-Fuel Inverter Generator is backed by a 3-годишна Ограничена гаранцијаОваа гаранција ги покрива дефектите во материјалите и изработката при нормална употреба и сервис. Ве молиме задржете го доказот за купување за гаранциски барања.

For specific terms and conditions of the warranty, please refer to the warranty card included with your product or visit the official GENMAX webсајт.

8.2 Техничка поддршка

Should you encounter any issues or require assistance with your generator, GENMAX offers ongoing technical support. Please have your model number (GM12500iET) and serial number ready when contacting support.

Contact information for technical support can typically be found on the GENMAX website or in the documentation provided with your generator.

Поврзани документи - GM12500iET

Предview GENMAX GM12500iET Inverter Generator User's Manual
Comprehensive user's manual for the GENMAX GM12500iET Tri-Fuel Inverter Generator, covering safety, operation, maintenance, troubleshooting, and technical specifications. Learn how to safely operate and maintain your generator.
Предview Упатство за користење на генераторот со три горива и инвертер Genmax GM17000iETC
Comprehensive user's manual for the Genmax GM17000iETC Tri-Fuel Inverter Generator, covering operation, safety, maintenance, troubleshooting, and technical specifications. Learn how to safely operate and maintain your generator for gasoline, LPG, and natural gas fuels.
Предview Упатство за користење на генераторот со три-горива инвертер GENMAX GM17000iETC
Comprehensive user manual for the GENMAX GM17000iETC Tri-Fuel Inverter Generator, covering safety, operation, maintenance, troubleshooting, and technical specifications. Learn how to safely operate and maintain your generator for gasoline, LPG, and natural gas.
Предview Упатство за користење на генераторот со три-горивни инвертори GENMAX GM6250iET
Сеопфатно упатство за корисникот за генераторот со три горива GENMAX GM6250iET, кое ги опфаќа безбедноста, работењето, одржувањето, решавањето проблеми и техничките спецификации. Научете како безбедно да го ракувате и одржувате вашиот генератор.
Предview GENMAX GM10500XiT Tri-Fuel Inverter Generator User's Manual
This user manual provides comprehensive instructions for the GENMAX GM10500XiT Tri-Fuel Inverter Generator, covering safety guidelines, operation procedures, maintenance schedules, troubleshooting tips, and technical specifications to ensure safe and efficient use.
Предview Упатство за користење на генераторот со три горива и инвертер Genmax GM11000iET
Сеопфатно упатство за корисникот за генераторот со три горива Genmax GM11000iET, кое опфаќа безбедносни упатства, работа, одржување, решавање проблеми и технички спецификации.