Предговор
Thank you for choosing the INVT EC-PG805-05 TTL incremental encoder PG expansion module. The EC-PG805-05 TTL incremental encoder PG expansion module is used with the GD880 series VFD control box to detect the TTL or RS422 incremental encoder. The expansion module monitors the rotational speed of the motor by detecting the output signal of the encoder, providing real-time speed feedback for precise speed control. This manual describes the product overview, installation, wiring, and commissioning instructions. Before installing the VFD, read through this manual carefully to ensure proper installation and running with excellent performance and powerful functions in full play.
Карактеристики на производот
- Incremental encoder multi-channel signal detection: IA+, IA -, IB+, IB -, IZ+, IZ-
- Provides power supply for encoders: 5V±5%/150mA
- Supports two input signal types: TTL differential signal input, RS422 signal input
- Поддржува референца на пулсот и излез на поделба на фреквенцијата
- With the encoder disconnection detection function, it avoids the expansion of the system fault impact
- Може да ја открие температурата на моторот преку сигналот од сензорот за температура KTY84/PT100
- Adopts digital filtering technology to improve electromagnetic compatibility and realize long-distance stable reception of encoder signals.
Производот завршиview
Опис на моделот

Спецификации

Табела 1-1 Спецификации
Технички параметри

Табела 1-2 Технички параметри
Забелешка: The Disconnection detection function is only supported when the motor is running.
Структура
Figure 1-2 Component diagram

Табела 1-3 Опис на компонентата

Инсталација и жици
Мерки на претпазливост при инсталација
Required tools: Phillips screwdriver PHl, straight screwdriver SL3

Табела 2-1 Screw torque requirements

Димензии
The dimensions of the PG expansion module are 73.5x 103 x 34 mm (W*H*D).

Инструкции за инсталација

It is recommended to place the PG expansion module in expansion slot 1 of the control box. The following is an exampод инсталацијата на слот 1.
Чекор 1: Поставете го модулот за проширување во соодветната положба на отворот за проширување на контролната кутија 1, порамнете го со отворот и потоа спојте го заедно.
Чекор 2: Align the expansion module positioning hole with the positioning stud.
Чекор 3:F: Fix with an M3 screw. The installation is complete.
Забелешка
- Модулот за проширување и контролната кутија се електрично поврзани преку слотови. Ве молиме инсталирајте ги на место.
- За да обезбедите сигурна работа на модулот за проширување и да ги исполните барањата за EMC, затегнете ги завртките според препорачаниот вртежен момент за сигурно заземјување.
Инструкции за расклопување
You disassemble the module by reversing the order of steps described in section 2.3 Installation instructions.
Чекор 1: Disconnect all power supplies and disassemble all cables connected to the expansion module.
Чекор 2: Use a Phillips screwdriver PHl to remove the grounding screws of the expansion module.
Чекор 3: Lift the expansion module out of the control box, positioning stud, and pull it out to a suitable position. Disassembly is complete.
Терминал за ожичување на корисникот


Забелешка
- The number of the PG extension module that supports the KTY84 type and that supports the PT100 type are different. Please note this when placing an order.
- The PG expansion module supports one PT100 or three PT100s for use in series.
Табела 2-3 Дефиниција на функцијата на терминалот X4

Table 2-4 Function definition of RJ45 interfaces X1-X2

Figure 2-3 External wiring diagram when using EC-PG805-05

Забелешка: For the PT100 temperature sensor application (in a 3-channel series connection), J3 should be shortened.
Мерки на претпазливост за поврзување
Забелешка
- За ожичување на енкодерот во внатрешноста на кабинетот, одвојте ги од каблите за силни пречки (како кабли за напојување) со препорачан интервал од 30 см.
- За ожичување на енкодерот надвор од кабинетот, избегнувајте паралелно поврзување со кабелот за напојување и избегнувајте формирање на прстенест облик. Доколку условите дозволуваат, се препорачува да се користи метален канал за жици.
- To ensure high anti-interference capability in closed-loop control, you need to use a shielded wire for encoder cables and ground both ends of the cable, that is, connect the shielding layer on the motor side to the motor housing, and connect the shielding layer on the PG module side to the PE terminal.
Упатство за пуштање во работа


Table 3-1 Function code parameters related to PG expansion module.


Забелешка: For other parameter settings of the EC-PG805-05 TTL incremental encoder PG expansion module, see the software manuals of the GD880 series inverter unit.
Документи / ресурси
![]() |
invt EC-PG805 TTL Incremental Encoder PG Expansion Module [pdf] Упатство за користење 66001-01189, EC-PG805 TTL Incremental Encoder PG Expansion Module, EC-PG805, TTL Incremental Encoder PG Expansion Module, Incremental Encoder PG Expansion Module, Encoder PG Expansion Module, PG Expansion Module, Expansion Module, Module |